CRS-311 1:1 Redundancy Switch
Revision 7
Cables and Connections
MN/CRS311.IOM
3–30
3.3.6
Ethernet Data Traffic Connections – CRS-311 to Modems
3.3.6.1 Ethernet Bridge Mode Data Traffic via the Optional GbE Interface
When
the
SLM
‐
5650/5605A
modems
are
equipped
with
the
optional
single
‐
port
10/100/1000
BaseT
(GbE)
Interface
Module,
Single
‐
Port
Ethernet
Bridge
Mode
is
possible:
•
Configuration
‘A’
–
Referring
to
Figure
3
‐
17
,
when
the
CRS
‐
311
is
configured
with
the
CRS
‐
306
or
CRS
‐
307
RMI
and
CRS
‐
316
or
CRS
‐
336
TMI,
connect
and
secure
all
PP/CAT5FF3FTGY
CAT5
Data
Cables
as
follows:
o
From
the
RJ
‐
45
connector
labeled
“J5”
on
the
RMI
or
TMI,
to
the
RJ
‐
45
connector
labeled
“J1”
on
the
Redundant
or
Traffic
Modem
optional
GbE
Interface
Module.
•
Configuration
‘B’
–
Referring
to
Figure
3
‐
18
,
when
the
CRS
‐
311
is
configured
with
the
CRS
‐
505
RMI
and
CRS
‐
515
TMI,
connect
and
secure
all
PP/CAT5FF3FTGY
CAT5
Data
Cables
as
follows:
o
From
the
RJ
‐
45
connector
labeled
“Port
2”
on
the
RMI
or
TMI
to
the
RJ
‐
45
connector
labeled
“J1”
on
the
Redundant
or
Traffic
Modem
optional
GbE
Interface
Module.
3.3.6.2 Ethernet Bridge Mode
Data Traffic via the Optional Network
Processor (NP) Interface
When
the
SLM
‐
5650/5605A
modems
are
equipped
with
the
optional
multi
‐
port
Network
Processor
(NP)
Interface
Module,
Multi
‐
Port
Ethernet
Bridge
Mode
is
possible.
Referring
to
Figure
3
‐
19
,
connect
and
secure
all
PP/CAT5FF3FTGY
CAT5
Data
Cables
as
follows:
•
From
the
RJ
‐
45
connectors
labeled
“Port
2”
through
“Port
4”
on
the
RMI
or
TMI,
to
the
RJ
‐
45
connectors
labeled
“Port
2”
through
“Port
4”
on
the
Redundant
or
Traffic
Modem
optional
Network
Processor
(NP)
Interface
Module.
Do
not
connect
to
“Port
1”
on
the
RMI,
TMI,
or
to
Port
“1”
on
the
optional
Network
Processor
(NP)
Interface
when
operating
in
Multi
‐
Port
Ethernet
Bridge
Mode.
Do
not
connect
to
Port
1
on
the
RMI
or
TMI
when
operating
in
Single
‐
Port
Ethernet
Bridge
Mode.
Содержание CRS-311
Страница 12: ...CRS 311 1 1 Redundancy Switch Revision 7 Table of Contents MN CRS311 IOM xii This page is intentionally blank...
Страница 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Страница 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Страница 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Страница 108: ...CRS 311 1 1 Redundancy Switch Revision 7 Modem RMI TMI and Switch Configuration MN CRS311 IOM 4 20 Notes...
Страница 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Страница 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Страница 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Страница 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...
Страница 194: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...