CDM-Qx Satellite Modem
Revision 6
Front Panel Operation
MN/CDMQx.IOM
this solid block cursor would obscure the item being edited (for example, a numeric field)
the cursor automatically changes to an underline cursor.
If the user were to display the same screen for weeks at a time, the display could become
‘burnt’ with this image. To prevent this, the unit has a ‘screen saver’ feature that activates
after 1 hour. The top line of the display will show the Circuit ID (which can be entered by
the user) and the bottom line will show the circuit Eb/No value (if there is a demod and it
is locked) followed by ‘
Press any key....
’. The message moves from right to left across
the screen, then wraps around. If there are multiple circuits, their messages and Eb/No’s
will be displayed sequentially. Pressing any key restores the previous screen. The
behavior of the front panel LEDs is described below in Table 5-1.
Table 5-1. Front Panel LED Indicators
LED
Color
Condition
Red
A Unit Fault exists (Example: PSU fault)
Green
No Unit Faults
Unit
Status
Note: Unit fault does not include Tx or Rx fault.
Green
No Tx Traffic Faults
Off
A Tx Traffic fault exists or the Tx Carrier is in OFF state
Transmit
Traffic
Note: This LED corresponds to the selected slot, example <TX>.
Green
No Rx Traffic Faults (demod and Viterbi decoder are locked, everything is OK)
Off
An Rx Traffic fault exists (the demod may still be OK – check the fault status of the
unit from the Monitor menu).
Receive
Traffic
Note: This LED corresponds to the selected slot, example <RX>.
Green
The Unit is On Line, and carrying traffic
Off
The Unit is Off Line (standby) - forced by externally connected 1:1 or 1:N
redundancy system
Online
Note: This LED corresponds to the selected slot, example <RX>.
Orange
There is a Stored Event in the log, which can be viewed from the front panel, or
retrieved via the remote control interface
Stored Event
Off
There are no Stored Events
Orange
The Unit is in Remote Mode - local monitoring is possible, but no local control
Off
The Unit is in Local Mode - remote monitoring is possible, but no remote control
Remote
Flashing
ODU FSK control has been enabled, and there is a communications fault.
Orange
Framing on, EDMAC on, and unit defined as Slave - local monitoring is possible,
but no local control
EDMAC Mode
Off
Either the unit is in Transparent mode (no framing), or the framing has been
selected, but in AUPC-only mode, or EDMAC Master configuration.
Orange
A Test Mode is selected (example: IF Loopback), or BERT Generator is turned on,
or BERT Monitor is turned on, or Spectrum Analyzer is turned on.
Test Mode
Off
There is no Test Mode currently selected, BERT Generator is off, BERT Monitor is
off, and spectrum Analyzer is off.
IMPORTANT
In general, the Alarm relay state will reflect the state of the Front Panel LEDs. For
instance, if the Unit Status LED is red, the Unit Alarm relay will be active, etc. The
one exception is the Transmit Traffic relay. This will only be activated if a Transmit
Traffic Fault exists – it does not reflect the state of the TX carrier.
5–2
Содержание CDM-Qx
Страница 2: ......
Страница 4: ...This page is intentionally blank...
Страница 26: ...CDM Qx Satellite Modem Revision 6 Introduction MN CDMQx IOM Notes 1 8...
Страница 112: ...CDM Qx Satellite Modem Revision 6 Front Panel Operation MN CDMQx IOM Notes 5 64...
Страница 132: ...CDM Qx Satellite Modem Revision 6 EDMAC Channel MN CDMQx IOM This page is intentionally blank 7 4...
Страница 154: ...CDM Qx Satellite Modem Revision 6 Ethernet Management Base Modem MN CDMQx IOM 11 12...
Страница 166: ...CDM Qx Satellite Modem Revision 6 Flash Upgrading MN CDMQx IOM Notes B 4...
Страница 174: ...CDM Qx Satellite Modem Revision 6 Remote Control MN CDMQx IOM Notes C 8...
Страница 224: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...