CDM-Qx Satellite Modem
Revision 6
Summary of Specifications
MN/CDMQx.IOM
A.7
Miscellaneous
Front panel
Tactile keypad, 6 keys (Up/Down, Left/Right, Enter/Clear)
Vacuum Fluorescent Display (blue) - 2 lines of 40 characters
Loopbacks
Internal IF loopback, RF loopback, digital loopback, and inward/outward loopback
Fault relays
Hardware fault, RX and TX Traffic Alarms
M&C Interface
EIA-232 and EIA-485 (addressable multidrop, 2-wire or 4-wire), 10/100 BaseT Ethernet
M&C Software
SATMAC software for control of local and distant units
AC Consumption
(Depends on configuration)
120 watts (maximum) for 70/140,
250 watts (maximum for L-Band
AC Operating Voltage
100 to 240 VAC, +6%/-10% - autosensing
(total absolute max. range is 90 to 254 VAC)
DC Operating Voltage
36 to 72 VDC, 6.25 amps
Temperature:
Operating
Storage
0 to 50
o
C (32 to 122
o
F)
-25 to 85
o
C (-13 to 185
o
F)
Dimensions
1.75H x 19W x 19D inches (4.4H x 48W x 48D cm)
Weight
< 20 lbs (7.0 kg) approx (depends on configuration)
CE Mark
EMC Safety
FCC
Part 15
A–8
Содержание CDM-Qx
Страница 2: ......
Страница 4: ...This page is intentionally blank...
Страница 26: ...CDM Qx Satellite Modem Revision 6 Introduction MN CDMQx IOM Notes 1 8...
Страница 112: ...CDM Qx Satellite Modem Revision 6 Front Panel Operation MN CDMQx IOM Notes 5 64...
Страница 132: ...CDM Qx Satellite Modem Revision 6 EDMAC Channel MN CDMQx IOM This page is intentionally blank 7 4...
Страница 154: ...CDM Qx Satellite Modem Revision 6 Ethernet Management Base Modem MN CDMQx IOM 11 12...
Страница 166: ...CDM Qx Satellite Modem Revision 6 Flash Upgrading MN CDMQx IOM Notes B 4...
Страница 174: ...CDM Qx Satellite Modem Revision 6 Remote Control MN CDMQx IOM Notes C 8...
Страница 224: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...