CDM-Qx Satellite Modem
Revision
6
Remote Control
MN/CDMQx.IOM
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for
Command or
Response to
Query
Description of arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
BUC Low Current
Limit
BCL=
4 bytes
Command or Query
BCL=
BCL? BCL=xxxx
BUC Low Current Limit, a value between 100 and 3000 mA
BCL?
(see description of
arguments)
(L-Band Unit
only)
BCL*
Example: BCL=0600
BCL#
BCL^
BUC LO
Frequency
BLO=
6 bytes
Command or Query
BLO=
BLO? BLO=xxxxxs
BUC transmit LO frequency information in the form: xxxxxs, where :
BLO?
(see description of
arguments)
(L-Band Unit
only)
xxxxx is the LO frequency in the range of 3000 to 65000 MHz
BLO*
All 0’s (000000) disables the feature
BLO#
S is the sign for the mix (+ or – character)
BLO^
Terminal Frequency= BUC LO TFQ
Example: BLO=12000+ (BUC LO is 12 GHz, low-side mix)
BUC Output
Power Level
N/A
4 bytes
Query only
N/A BOL?
BOL=xx.x
BUC output power level in the form xxx, where xxx is the value in
watts.
(see description of
arguments)
(L-Band Unit
only)
Example: BOL=08.3 (BUC reports output is 8.3 watts)
Returns 00.0 when FSK and BUC power are not enabled.
BUC
Temperature
N/A
4 bytes
Query only
N/A
BUT?
BUT=sxx
Indicates BUC temperature, in the form: sxxx
(see description or
arguments)
(L-Band Unit
only)
Where:
s=sign (+ or – character)
xx=value
If not available, response is –99
Example: BUT=-13 (BUC temperatures is -13
°
C)
Note: This query is only valid when the FSK and BUC power are turned On.
BUC PLL Alarm
N/A
1 byte, value of
0,1
Query only
N/A BPA?
BPA=x
(L-Band Unit
only)
BUC PLL lock state, where:
(see description of
arguments)
0=Unlocked
1=Locked
Example: BPA=1 (BUC PLL is locked)
Note: This query is only valid when the FSK and BUC power are turned On
BUC Software
Version
N/A
3 bytes
Query only
N/A BSV?
BSV=x.x
Indicates the BUC software version, in the form: x.x
(see description of
arguments)
(L-Band Unit
only)
Example: BSV=1.1 (Software version 1.1)
Note: This query is only valid when the FSK and BUC power are turned On
C-37
Содержание CDM-Qx
Страница 2: ......
Страница 4: ...This page is intentionally blank...
Страница 26: ...CDM Qx Satellite Modem Revision 6 Introduction MN CDMQx IOM Notes 1 8...
Страница 112: ...CDM Qx Satellite Modem Revision 6 Front Panel Operation MN CDMQx IOM Notes 5 64...
Страница 132: ...CDM Qx Satellite Modem Revision 6 EDMAC Channel MN CDMQx IOM This page is intentionally blank 7 4...
Страница 154: ...CDM Qx Satellite Modem Revision 6 Ethernet Management Base Modem MN CDMQx IOM 11 12...
Страница 166: ...CDM Qx Satellite Modem Revision 6 Flash Upgrading MN CDMQx IOM Notes B 4...
Страница 174: ...CDM Qx Satellite Modem Revision 6 Remote Control MN CDMQx IOM Notes C 8...
Страница 224: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...