background image

 User 

Manual

 

Desktop: 

MDS932AE-10BT-R2 

MDS932AE-FXO-R2 

MDS932AE-FXS-R2 

MDS933AE-10BT-R2 

 

Rack Cards: 

MDS932C-1-R2 

MDS932C-2-R2 / MDS933C-R2 

 

G.SHDSL Modem following the Restriction of Hazardous Substances Directive (RoHS)

 

USER MANUAL 

 

Version   

 

1.9 

Revision 

 

22. May 2006 

Document name 

MDS932-933AE-10BT-R2_FXO-FXS-R2.doc 

Содержание MDS932AE-10BT-R2

Страница 1: ...MDS932AE FXS R2 MDS933AE 10BT R2 Rack Cards MDS932C 1 R2 MDS932C 2 R2 MDS933C R2 G SHDSL Modem following the Restriction of Hazardous Substances Directive RoHS USER MANUAL Version 1 9 Revision 22 May 2006 Document name MDS932 933AE 10BT R2_FXO FXS R2 doc ...

Страница 2: ...ranscribed stored in a retrieval system translated into any language or transmitted in any form or by any means electronic mechanical magnetic optical chemical photocopying manual or otherwise without the prior written permission of Black Box Network Services Published Black Box Network Services All rights reserved Version 1 9 Page 2 of 29 ...

Страница 3: ...onfiguration 13 4 THE COMMAND SYSTEM 14 4 1 Basic rules 14 4 2 The main menu 14 4 3 Performance management submenu 15 4 3 1 Loop Status submenu 15 4 3 2 Ethernet Status submenu 16 4 3 3 HDLC Status submenu 17 4 4 Configuration management submenu 17 4 4 1 DSL Setup 18 4 4 2 Ethernet Setup submenu 20 4 4 3 Profile submenu 21 4 4 4 Erase NVRAM 21 4 4 5 Security Auto Lock 21 4 5 Security management su...

Страница 4: ...Desktop units MDS932 933AE 10BT R2 26 9 2 DSL Connector for RACK CARD units MDS932C 1 2 R2 MDS933C R2 26 9 3 Monitor Connector 27 9 4 PC and Hub Connectors 27 9 5 Line1 and Line2 Connector MDS932AE FXO FXS R2 28 10 DESCRIPTION OF INTERFACE CABLES 29 10 1 Ethernet cable 29 10 2 DSL cable 29 Version 1 9 Page 4 of 29 ...

Страница 5: ...Connecter drawing 8 2 Manual corresponding to software version 1 8 Small Text changes 1 4 11 02 2005 Manual corresponding to software version 1 9s SNMP topic implemented TFTP topic implemented Small Text changes 1 5 02 08 2005 Manual corresponding to software version 2 4 CE Model implemented TFTP topic modified 1 6 09 09 2005 Manual corresponding to software version 2 44 Modified 4 4 1 3 TFTP topi...

Страница 6: ...marked with the above recycling symbol It means that at the end of the life of the equipment you must dispose of it separately at an appropriate collection point and not place it in the normal domestic unsorted waste stream European Union only Version 1 9 Page 6 of 29 ...

Страница 7: ... line speed adjustment Ethernet 10 100Base T interface Full Half duplex Transmission of VLAN packet IEEE 802 1Q Dynamic table formation of MAC addresses Accumulation of up to 1024 MAC addresses Granting of 95 of the digital channel band to the user In built functions of diagnostics and self testing Low power consumption easy to use applications Console port for the local management Telnet port for...

Страница 8: ... connection the correspondence of the signal to noise ratio which does not allow to transmit information and a great number of errored blocks can cause an urgent alarm See the Command menu chapter for detail amber informs the user about non urgent alarms An abruption of connection over the user s interface can cause non urgent alarms green absence of alarms Normal functioning of the device WAN Res...

Страница 9: ...rnal power supply unit the DSL connector to connect the modem to the leased physical line the Monitor connector to control the modem and store statistics HUB connector to connect the modem to the LAN using a straight Patch Cord The back panel of the MDS932AE FXO R2 and MDS932AE FXS R2 modem has additionally The LINE1 PORT1 and LINE2 PORT2 connector to connect to PABX FXO model or to telephone FXS ...

Страница 10: ...User Manual 2 2 Exterior design Rack Card models MDS932C 1 2 or MDS933C R2 Version 1 9 Page 10 of 29 ...

Страница 11: ...nal to noise ratio which does not allow to transmit information and a great number of errored blocks can cause an urgent alarm amber informs the user about non urgent alarms An abruption of connection over the user s interface can cause non urgent alarms green absence of alarms Normal functioning of the device Status R informs the user about the status of the remote device At the time being the re...

Страница 12: ... connect the modem using the straight Patch Cord cable to the hub through the HUB connector or to the PC through the PC connector Only one device can be connected to modem jack at same time connect the modem if necessary to the serial port of the PC through the MONITOR connector using the straight modem cable connect the modem to the line using the DSL connector connect the power supply unit to th...

Страница 13: ...er key The following menu will appear on the screen Input Password Please enter your programmed password The unit will be delivered with the default password admin After entering the password the following menu will appear Discovery G SHDSL Ethernet Monitor V2 46 Main Menu 1 Performance management PM 3 Configuration management CM 4 Security management SM 5 Exit Console Select item number or ESC to...

Страница 14: ...o up menu screen 4 2 The main menu The main menu is the following Discovery G SHDSL Ethernet Monitor V2 46 Main Menu 1 Performance management PM 3 Configuration management CM 4 Security management SM 5 Exit Console Select item number or ESC to Upper level menu The menu consists of five submenus To choose the needed submenu it is necessary to type its number and press Enter The main menu also conta...

Страница 15: ...tion of the performance management submenu the following message will be displayed Performance Management Loop Status System Up Time 0 Day 00 16 31 Loop 1 Loop Up Time 0 Day 00 15 07 Operation State Data Line Speed 2312K Rx Gain 5 43 dB Tx Power 14 50 dBm S N Ratio 37 74 dB Framer Status In sync Loop Atten 0 19 dB Operation Mode Slave Auto Fixed Fixed Clock Source Follow Loop Annex A B Fixed Speed...

Страница 16: ...essage will be displayed Performance Management EtherNet Status Link Link down Link Speed Link Duplex Used Entries 0 Tx Packets 0 Rx Packets 0 Fwd Packets 0 Drop Packets 0 Speed Auto Duplex Auto MAC Address 00 00 00 00 00 00 1 Clear Counters Select item number or ESC to Upper level menu Version 1 9 Page 16 of 29 ...

Страница 17: ...lear Counter s Select item number or ESC to Upper level menu 4 4 Configuration management submenu Upon activation of the configuration management submenu the following message will be displayed Configuration Management 1 DSL Setup 4 EtherNet Setup 6 Profile 7 Erase NVRAM 9 Security Auto Lock 70 Seconds System Information Boot Loader Version BL 2 45 Build 0001 Date May 12 2006 19 49 56 Application ...

Страница 18: ...he unit to one of the following states Master Slave 4 4 1 2 Auto Fixed This Menu is only available if the 4W unit is in 1 1 mode This Menu is NOT available if the 4W unit is in 4W mode In this Menu you can setup the unit to one of the following states Auto Fixed If Auto is selected the unit works in the adaptive mode If Fixed is selected the unit works with fixed line rates 4 4 1 3 Min Max Connect...

Страница 19: ...ou can setup you desired TX output level in the range from 2dB to 13dB Please note changing the default value of 0 to another value may cause serious malfunction of the DSL line It should be changed only by qualified personal 4 4 1 7 2W 2CH 4W 1 1 In the 2W 4W 2 wire 4 wire Adjustments menu you can setup you desired number and mode of the DSL line The following modes are possible 2W 1 DSL line nor...

Страница 20: ...n setup the Ethernet ports to the following states Half Full or Auto In the IP Address Subnet Mask and Gateway Address menu you can setup the desired IP settings In the NMS IP Address menu you can setup the IP receiver address for the SNMP traps the Network Manager In the Read Write Trap Community menu you can setup the desired SNMP community address names text In the Enable TFTP Server menu you c...

Страница 21: ... can erase the non volatile ram This function will force some part of the unit to there factory default values 4 4 5 Security Auto Lock During this time the user must set up password for the modem This is also the time after a telnet session will be terminated in case of no terminal action 4 5 Security management submenu The security management is using for setting the desired password for the con...

Страница 22: ...nzip the download file to an empty directory If necessary rename the actual bin file to all bin Open the cmd exe windows menu Start Run cmd Enter the directory with the unzipped files Enter the following command TFTP I xxx xxx xxx xxx PUT all bin Wait until the program terminates check it on the PC Terminal Close the cmd exe windows menu 5 3 Unit termination Enter the Ethernet Setup submenu Enter ...

Страница 23: ...upports the following traps Trap Description Cold start Sent on unit startup Linkup Sent on DSL link up Linkdown Sent on DSL link loss Authorization Error Sent on reception of a wrong community string hacker attack Version 1 9 Page 23 of 29 ...

Страница 24: ...ine code G shdsl TC PAM Input impedance of the physical line 135 Ohm Output signal level 0 5dBm 15 5 dBm Transmission spectrum from 0 450 kHz User s interface Standard IEEE 802 3 IEE 802 1Q Interface type Ethernet 10 100Base T Full Half Duplex Connector RJ 45 Management Monitoring VT100 Power supply Supply voltage DESKTOP model 230 Vac 10 50 Hz power adapter RACK CARD model 36Vdc 72Vdc Power consu...

Страница 25: ...nths from the date of transshipment including transporting time in storage rooms without heating at 50о С 50о С and the mean monthly value of the air humidity of 80 at 20о С short term increases of air humidity up to 98 no more than a month a year at a temperature not exceeding 25о С without moisture condensation is admissible The equipment should be stored in storage buildings which protect the d...

Страница 26: ...ent 1 2 NC 3 LB a Ttp 4W model only 4 LA a tip 5 LA b ring 6 LB b ring 4W model only 7 8 NC RJ 45 1 8 9 2 DSL Connector for RACK CARD units MDS932C 1 2 R2 MDS933C R2 Type RJ 45 8 pin Number Signal Assignment 1 LB a tip 4W model only 2 LB b ring 4W model only 3 NC 4 LA a tip 5 LA b ring 6 7 8 NC RJ 45 1 8 Version 1 9 Page 26 of 29 ...

Страница 27: ...Transmit data 3 RXD Receive data 4 DTR Data terminal ready 5 SGND Signal ground 6 NC 7 NC 8 NC 9 NC DB9 female 1 5 6 9 9 4 PC and Hub Connectors Type RJ 45 Number PC assignment HUB assignment 1 Tx Rx 2 Tx Rx 3 Rx Tx 4 NC NC 5 NC NC 6 Rx Tx 7 NC NC 8 NC NC 1 8 RJ 45 Version 1 9 Page 27 of 29 ...

Страница 28: ...User Manual 9 5 Line1 and Line2 Connector MDS932AE FXO FXS R2 Type RJ 11 4 pin Number Signal Assignment 1 NC 2 LA a tip 3 LA b ring 4 NC RJ 11 1 4 Version 1 9 Page 28 of 29 ...

Страница 29: ...1 2 green white 2 3 white orange 3 4 blue white 4 5 white blue 5 6 orange white 6 7 white brown 7 8 brown white 8 10 2 DSL cable Side А Color of wire Side B 1 white green 1 2 green white 2 3 white orange 3 4 blue white 4 5 white blue 5 6 orange white 6 7 white brown 7 8 brown white 8 Version 1 9 Page 29 of 29 ...

Отзывы: