CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Installation
MN-CDM750
2–2
This
equipment
contains
parts
and
assemblies
sensitive
to
damage
by
Electrostatic
Discharge
(ESD).
Use
ESD
precautionary
procedures
when
handling
the
equipment.
Once
opened,
inspect
the
shipment
Step
Task
1
Keep
all
shipping
materials
for
storage
or
reshipment.
2
Check
the
packing
list
to
ensure
the
shipment
is
complete.
3
Inspect
the
equipment
for
any
possible
damage
incurred
during
shipment.
Contact
the
carrier
and
Comtech
EF
Data
immediately
to
submit
a
damage
report
if
damage
is
evident.
4
Review
this
CDM
‐
750
Advanced
High
‐
Speed
Trunking
Modem
Installation
and
Operation
Manual
carefully
to
become
familiar
with
operation.
5
Proceed
to
Sect.
2.2
Installation
into
a
Rack
Enclosure.
2.2
Installing into a Rack Enclosure
When
mounting
the
CDM
‐
750
into
a
rack
enclosure
•
PROPER
GROUNDING
PROTECTION
IS
REQUIRED.
The
equipment
must
be
connected
to
the
protective
earth
connection
at
all
times.
It
is
therefore
imperative
that
the
unit
is
properly
grounded,
using
the
ground
stud
provided
on
the
unit
rear
panel,
during
installation,
configuration,
and
operation.
•
PROPER
AIR
VENTILATION
IS
REQUIRED.
In
a
rack
system
where
there
is
high
heat
discharge,
provide
forced
‐
air
cooling
with
top
‐
or
bottom
‐
mounted
fans
or
blowers.
o
Make
sure
there
is
adequate
clearance
inside
the
enclosure,
especially
at
the
side
for
air
ventilation.
o
Air
temperature
inside
the
rack
enclosure
should
never
exceed
50
°
C
(122
°
F).
For
information
about
custom
rack
enclosures,
contact
Comtech
EF
Data
Customer
Support
during
normal
business
hours
or
visit
Comtech
EF
Data’s
Web
site
(www.comtechefdata.com/support.asp).
Содержание CDM-750
Страница 64: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Rear Panel Connections MN CDM750 3 20 Notes...
Страница 76: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Updating Firmware MN CDM750 4 12 Notes...
Страница 142: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Front Panel Operation MN CDM750 5 66 Notes...
Страница 178: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Ethernet based Remote Product Management MN CDM750 6 36 Notes...
Страница 224: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix A MN CDM750 A 4 Notes...
Страница 227: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 3 This page is intentionally blank...
Страница 234: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 10 Notes...
Страница 256: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix C MN CDM750 C 22 Notes...
Страница 280: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix D MN CDM750 D 24 Notes...
Страница 300: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...