CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Appendix C
MN-CDM750
C–19
The CDM-750 Ethernet
Switch auto-negotiates
Pause Frame compatibility
C.6.1 ACM Congestion Control
See
Sect.
5.2.2.1.4
(CONFIG)
INTF:
GBEIX
in
Chapter
5.
FRONT
PANEL
OPERATION
for
detailed
information
on
Flow
Control.
When
the
ACM
controller
switches
from
a
lower
to
a
higher
ModCod,
the
bandwidth
of
the
WAN
link
is
instantaneously
increased.
This
is
not
a
problem,
as
the
link
will
adapt
to
push
more
packets/second
through
the
link.
Conversely,
when
the
ACM
controller
switches
from
a
higher
to
a
lower
ModCod,
the
bandwidth
of
the
WAN
link
is
instantaneously
reduced.
Figure C-8. CDM-750 – ACM Congestion Control
As
shown
in
,
in
order
to
mitigate
packet
loss
when
bandwidth
is
reduced,
the
CDM
‐
750
incorporates
a
WAN
buffer.
When
this
WAN
buffer
cannot
accommodate
the
amount
of
Ethernet
traffic
due
to
the
WAN
bandwidth,
the
CDM
‐
750
can
be
configured
to
initiate
a
method
for
congestion
control.
The
means
to
do
this
is
by
enabling
Flow
Control
.
When
Flow
Control
is
Enabled
,
the
WAN
buffer
produces
two
control
signals
that
enable
and
disable
the
sending
of
Ethernet
Pause
Frames
–
Ethernet
frames
designed
to
implement
flow
control
at
the
MAC
layer.
A
switch
supporting
802.3x
can
send
a
Pause
Frame
(with
Pause
time
set
to
0xFFFF)
to
force
the
link
partner
to
stop
sending
data.
Devices
use
the
Auto
‐
Negotiation
protocol
to
discover
the
Pause
Frame
capabilities
of
the
device
at
the
other
end
of
the
link.
In
,
it
can
be
seen
that
when
the
WAN
buffer
reaches
a
fill
state
of
87%,
it
signals
the
Ethernet
Switch
to
send
Pause
frames
back
to
the
LAN
to
inhibit
the
sending
of
further
data.
The
Pause
Frames
continue
to
be
sent
until
the
FIFO
fill
state
has
been
reduced
to
75%.
At
this
point,
normal
operation
in
resumed
by
sending
a
Pause
Frame
with
Pause
time
set
to
0x0000.
This
mechanism
has
been
shown
to
be
very
effective
at
mitigating
packet
loss
when
the
Ethernet
traffic
exceeds
the
WAN
capacity.
Содержание CDM-750
Страница 64: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Rear Panel Connections MN CDM750 3 20 Notes...
Страница 76: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Updating Firmware MN CDM750 4 12 Notes...
Страница 142: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Front Panel Operation MN CDM750 5 66 Notes...
Страница 178: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Ethernet based Remote Product Management MN CDM750 6 36 Notes...
Страница 224: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix A MN CDM750 A 4 Notes...
Страница 227: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 3 This page is intentionally blank...
Страница 234: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 10 Notes...
Страница 256: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix C MN CDM750 C 22 Notes...
Страница 280: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix D MN CDM750 D 24 Notes...
Страница 300: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...