CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Ethernet-based Remote Product Management
MN-CDM750
6–29
•
Rx
Clock
Source
–
Use
the
drop
‐
down
list
to
select
Tx
Clock
,
Ext
Clock
,
Rx
Sat
,
or
Int
Clock.
Comtech
EF
Data
strongly
recommends
that
you
select
Rx
Sat
unless
a
high
stability
External
Clock
is
present
and
timing
of
the
network
requires
all
devices
to
be
locked
to
the
External
Clock.
•
External
Clock
–
Use
the
drop
‐
down
list
to
set
the
expected
clock
rate
for
the
External
Clock
source
(via
the
CDM
‐
750
rear
panel
J8
|
EXT
REF
connector)
as
1
MHz
,
2
MHz
,
5
MHz
,
10
MHz
,
20
MHz
,
34.368
MHz
,
44.736
MHz
,
or
51.85
MHz
.
•
Rx
Buffer
Size
(ms)
–
Enter
a
buffer
size,
in
0.5
ms
steps,
ranging
from
2
ms
to
75
ms.
Click
[Configure
PIIC]
to
save
these
settings.
OC3 Configuration
•
Interface
Type
–
Use
the
drop
‐
down
list
to
select
None
or
OC3
.
•
Tx
Clock
Source
–
Use
the
drop
‐
down
list
to
select
Tx
Clock
or
Rx
Sat
.
Comtech
EF
Data
strongly
recommends
that
you
select
Tx
Clock
unless
a
high
stability
External
Clock
is
present
and
timing
of
the
network
requires
all
devices
to
be
locked
to
the
External
Clock.
•
Rx
Clock
Source
–
Use
the
drop
‐
down
list
to
select
Tx
Clock
,
Int
Clk
,
or
Rx
Sat
.
Comtech
EF
Data
strongly
recommends
that
you
select
Rx
Sat
unless
a
high
stability
External
Clock
is
present
and
timing
of
the
network
requires
all
devices
to
be
locked
to
the
External
Clock.
•
Rx
Buffer
Size
(ms)
–
Enter
a
buffer
size,
in
0.5
ms
steps,
ranging
from
2
ms
to
75
ms.
Alarm Settings
•
Tx
Symbol
Clock
PLL
–
Use
the
drop
‐
down
list
to
select
Alarm
,
Fault
,
Mask
,
or
Fault
(Tx
On)
.
•
Input
Signal
Loss
–
Use
the
drop
‐
down
list
to
select
Alarm
,
Fault
,
Mask
,
or
Fault
(Tx
On)
.
•
Rx
Buffer
Clock
PLL
–
Use
the
drop
‐
down
list
to
select
Alarm
,
Fault
,
or
Mask
.
•
Rx
Buffer
Overflow
/
Underflow
–
Use
the
drop
‐
down
list
to
select
Alarm
,
Fault
,
or
Mask
.
•
Ext
Clock
Activity
(G.703
PIIC
only)
–
(Indicates
that
the
External
Clock
is
selected
by
either
the
TxClock
or
RxClock
but
no
clock
is
present
on
J8
|
EXT
REF
.)
Use
the
drop
‐
down
list
to
select
Alarm,
Fault,
Mask
or
Fault
(Tx
On)
.
•
Ext
Clock
In
Range
(G.703
PIIC
only)
–
(Indicates
that
the
External
Clock
is
selected
by
either
the
TxClock
or
RxClock,
but
the
clock
rate
on
J8
|
EXT
REF
does
not
meet
the
expected
rate
by
the
CDM
‐
750.)
Use
the
drop
‐
down
list
to
select
Alarm,
Fault,
Mask
or
Fault
(Tx
On)
.
Содержание CDM-750
Страница 64: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Rear Panel Connections MN CDM750 3 20 Notes...
Страница 76: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Updating Firmware MN CDM750 4 12 Notes...
Страница 142: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Front Panel Operation MN CDM750 5 66 Notes...
Страница 178: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Ethernet based Remote Product Management MN CDM750 6 36 Notes...
Страница 224: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix A MN CDM750 A 4 Notes...
Страница 227: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 3 This page is intentionally blank...
Страница 234: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 10 Notes...
Страница 256: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix C MN CDM750 C 22 Notes...
Страница 280: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix D MN CDM750 D 24 Notes...
Страница 300: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...