CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Serial-based Remote Product Management
MN-CDM750
7–38
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
Faults and
Status
N/A
9 bytes
Query only.
Returns the current highest-priority fault and status codes for the Unit (hardware), TX Traffic, RX Traffic, and ODUs in the
form aabccdexx, where:
aa = Unit status:
00=No faults
01=Main Board Power Supply 3.3V
02=Main Board Power Supply 1.5V
03=Main Board Power Supply 1.2V
04=Main Board Power Supply 1.8V
05=Main Board Power Supply 1.9V
06=Main Board Power Supply 2.5V
07=Main Board Power Supply 1.25V
08=Modem Board Power Supply 5.5V
09=Modem Board Power Supply 3.8V
10=Modem Board Power Supply 2.3V
11=Modem Board Power Supply 3.3V
12=Modem Board Power Supply 1.8V
13=Modem Board Power Supply 1.2V
14=Tx Power Cal
15=FPGA Load Fail
16=Reference Unlocked
17=Temperature Exceeded
18=General Fault
19=General Test Fault
20=PIIC1 External Clock Activity
21=PIIC1 External Clock In Range
22=PIIC2 External Clock Activity
23=PIIC2 External Clock In Range
NOTE: External clocks are not valid with OC3 interface
24 =General Test - Unit forced Good
b = Tx status:
0=No Faults
1=Input Data
2=PLL
3=General Test Fault
4=PIIC1 Symbol Clock PLL
5=PIIC2 Symbol Clock PLL
6=PIIC1 Input Signal Loss
7=PIIC2 Input Signal Loss
8 =General Test - Tx forced Good
cc = Rx status:
00=No Fault
01=Demodulator unlocked
02=AGC Signal Level
N/A
FLT?
FLT=aabccdexx
(see Description of
Arguments)
Содержание CDM-750
Страница 64: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Rear Panel Connections MN CDM750 3 20 Notes...
Страница 76: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Updating Firmware MN CDM750 4 12 Notes...
Страница 142: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Front Panel Operation MN CDM750 5 66 Notes...
Страница 178: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Ethernet based Remote Product Management MN CDM750 6 36 Notes...
Страница 224: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix A MN CDM750 A 4 Notes...
Страница 227: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 3 This page is intentionally blank...
Страница 234: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 10 Notes...
Страница 256: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix C MN CDM750 C 22 Notes...
Страница 280: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix D MN CDM750 D 24 Notes...
Страница 300: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...