CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Serial-based Remote Product Management
MN-CDM750
7–23
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
GBEI Flow
Control
GFC=
1 byte, value
of 0 or 1
Command or Query.
Enable or disable flow control (applies to all ports) in the form x, where:
0 = Disable GBEI Flow Control
1 = Enable GBEI Flow Control
GFC=
GFC*
GFC#
GFC?
GFC=x (see
Description of
Arguments)
GBEI MAC
Learning
LRN=
1 byte, value
of 0 or 1
Command or Query.
Enable or disable MAC address learning (applies to all ports) in the form x, where:
0 = Disable MAC learning
1 = Enable MAC learning
LRN=
LRN?
LRN?
LRN=x (see
Description of
Arguments)
SNMP Read
Community
SRC=
16 bytes,
characters, no
spaces
Command or Query.
Set or return SNMP read community string. Empty string is not allowed
Example: <1/SRC=public
SRC =
SRC!
SRC?
SRC =x
(see description of
arguments)
SNMP
Write
Community
SWC=
16bytes,
characters, no
spaces
Command or Query.
Set or return SNMP write community string. Empty string is not allowed
Example: <1/SWC=private
SWC =
SWC!
SWC?
SWC =x
(see description of
arguments)
SNMP Trap
Destination IP
Address 1
STA=
15 bytes,
Numerical
Command or Query.
Set or return the IP address of the first SNMP Trap destination IP Address 1 where traps will be sent, in the form
xxx.xxx.xxx.xxx (the IP address).
Example: <1/STA=010.006.030.001
Returns >0001/STA=0.0.0.0 when not configured.
STA =
STA!
STA?
STA =
xxx.xxx.xxx.xxx
(see description of
arguments)
SNMP Trap
Destination IP
Address 2
STB=
15 bytes,
Numerical
Command or Query.
Set or return the IP address of the SNMP Trap destination IP Address 2 where traps will be sent, in the form
xxx.xxx.xxx.xxx (the IP address).
Example: <1/STB=010.006.030.001
Returns >0001/STB=0.0.0.0 When not configured.
STB =
STB!
STB?
STB =
xxx.xxx.xxx.xxx
(see description of
arguments)
SNMP
System
Contact
SSC=
255 bytes,
characters,
Command or Query.
Set or return SNMP System Contact string.
Example: <1/SSC=Joe Net Admin
If not configured it returns empty string: <1/SSC=
SSC =
SSC!
SSC?
SSC =x [1..128]
(see description of
arguments)
SNMP
Unit Name
SSN=
16 bytes,
characters,
Command or Query.
Set or return SNMP System Name string.
Example: <1/SSN=Remote1
If not configured it returns empty string: <1/SSC=
SSN =
SSN!
SSN?
SSN =x [1..128]
(see description of
arguments)
Содержание CDM-750
Страница 64: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Rear Panel Connections MN CDM750 3 20 Notes...
Страница 76: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Updating Firmware MN CDM750 4 12 Notes...
Страница 142: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Front Panel Operation MN CDM750 5 66 Notes...
Страница 178: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Ethernet based Remote Product Management MN CDM750 6 36 Notes...
Страница 224: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix A MN CDM750 A 4 Notes...
Страница 227: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 3 This page is intentionally blank...
Страница 234: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 10 Notes...
Страница 256: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix C MN CDM750 C 22 Notes...
Страница 280: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix D MN CDM750 D 24 Notes...
Страница 300: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...