CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Serial-based Remote Product Management
MN-CDM750
7–21
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
Retrieve next
5 unread
Stored Events
N/A
80 bytes
Query only.
Return the oldest 5 Stored Events which have not yet been read over the remote control in the form [CR]sub-
body[CR]sub-body[CR]sub-body[CR]sub-body[CR]sub-body, where Sub-body=ABCCddmmyyhhmmss:
A is fault/clear indicator where:
F=Fault
C = Clear
I = Info
B is the fault type where:
1 = Unit
2 = Rx Traffic
3 = Tx Traffic
4 = Info (Power on/off, or log cleared)
CC is Fault Code number, as in FLT? or Info Code, which may be:
0 = Power Off
1 = Power On
2 = Log Cleared
3 = Global Config Change
4 = Redundancy Config Change
ddmmyy = date stamp.
hhmmss = time stamp.
If there are less than five events to be retrieved, the remaining positions are padded with zeros. If there are no
new events, the response is RNE*.
N/A
RNE?
RNE=[CR]ABCCddm
myyhhmmss[CR]AB
CCddmmyyhhmmss[
CR]ABCCddmmyyhh
mmss[CR]ABCCddm
myyhhmmss[CR]AB
CCddmmyyhhmmss
(see description for
details of arguments)
Clear All
Stored Events
CAE=
None
Command only.
Forces the software to clear the events log.
Example: CAE=
CAE=
CAE?
CAE*
CAE#
N/A
N/A
Initialize the
Stored Events
Pointer
IEP=
None
Command only.
Resets internal pointer to allow RNE? queries to start at the beginning of the stored events log.
IEP=
IEP#
N/A
N/A
Management
IP Address
IPA=
18 bytes
numerical
Command or Query.
Set or return the IP Address and network prefix for the 10/100 Base-T Ethernet management port, in the format:
aaa.bbb.ccc.ddd.yy, where:
aaa = 000-223
bbb = 000-255
ccc = 000-255
ddd = 000-255
yy = network prefix (range: 8 to 31)
Example: IPA=010.006.030.001.24
IPA=
IPA?
IPA*
IPA#
IPA?
IPA=xxx.xxx.xxx.xxx.
yy
(see Description of
Arguments)
Содержание CDM-750
Страница 64: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Rear Panel Connections MN CDM750 3 20 Notes...
Страница 76: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Updating Firmware MN CDM750 4 12 Notes...
Страница 142: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Front Panel Operation MN CDM750 5 66 Notes...
Страница 178: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Ethernet based Remote Product Management MN CDM750 6 36 Notes...
Страница 224: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix A MN CDM750 A 4 Notes...
Страница 227: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 3 This page is intentionally blank...
Страница 234: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 10 Notes...
Страница 256: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix C MN CDM750 C 22 Notes...
Страница 280: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix D MN CDM750 D 24 Notes...
Страница 300: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...