8–10 Model 2100 and 2200 Ultra SCSI Controller Enclosures User Guide
ECB Battery Pack and ECB
This section describes ECB battery pack and ECB replacement procedures. Perform ECB
battery pack replacement procedures in an ESD-controlled environment. ECB
replacement procedures within an operating enclosure is array controller-specific.
Each ECB battery pack has a label (displaying a “born-on” date) that indicates when the
battery was tested and initially charged. Determine battery freshness by this “born-on”
date label (for example, DC:03MAR99 means that the battery received its initial charge on
March 3, 1999).
NOTE:
A fully discharged ECB battery pack takes up to 3.5 hours to charge completely.
Replacing an ECB Battery Pack
To replace an ECB battery pack, complete the procedure in Table 8–8.
NOTE:
The ECB battery pack is a sealed rechargeable lead acid battery that displays the
following label and must be recycled or disposed of properly after replacement.
Table 8–8 Replacing an ECB Battery Pack
1.
Remove the battery retaining bracket
2
by unscrewing the
retaining fastener
3
.
Pb
CXO6333A
1
2
3