D–8 Model 2100 and 2200 Ultra SCSI Controller Enclosures User Guide
0.3. **. 03
Noncritical
—Fan failure error. Replace the fan now.
**. = “01.” for Fan1, “02.” for Fan2, or “03.” for Fan3.
0.3. **. 04
Noncritical
—Fan missing error. Insufficient enclosure cooling. Install a fan soon.
**. = “01.” for Fan1, “02.” for Fan2, or “03.” for Fan3.
0.3. **. 05
Unrecoverable
—Fan missing failure. Insufficient enclosure cooling. Install a fan
now.
**. = “01.” for Fan1, “02.” for Fan2, or “03.” for Fan3.
0.4. **. 01
Noncritical
—High Temperature alert. Check for an empty bay or for a high operating
environment ambient air temperature. Fill any open bay with the required element or
blank bezel. Reduce the operating environment ambient air temperature to within
environmental specifications (see Appendix B).
**. = “01.” for PS1, “02.” for PS2, or “03” for EMU
0.4. **. 02
Critical
—High Temperature error. Check for an empty bay or for a high operating
environment ambient air temperature. Fill any open bay with the required element or
blank bezel. Reduce the operating environment ambient air temperature to within
environmental specifications (see Appendix B).
**. = “01.” for PS1, “02.” for PS2, or “03” for EMU
0.4. **. 03
Noncritical
—Low Temperature alert. Check for low operating environment ambient
air temperature. Fill any open bay with the required element or blank bezel. Increase
the operating environment ambient air temperature to within environmental
specifications (see Appendix B).
**. = “01.” for PS1, “02.” for PS2, or “03” for EMU
0.4. **. 04
Critical
—Low Temperature error. Check for low operating environment ambient air
temperature. Fill any open bay with the required element or blank bezel. Increase the
operating environment ambient air temperature to within environmental
specifications (see Appendix B).
**. = “01.” for PS1, “02.” for PS2, or “03” for EMU
Table D–3 Error Code List (Continued)
Error Code
Problem Definition/Corrective Action