Configuring an Array
Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
7-31
COMPAQ CONFIDENTIAL
Writer: Amy L. Laffitte File Name: h-ch7 Configuring an Array
Codename: Executor Part Number: 266328-001 Last Saved On: 2/8/02 10:39 AM
Adding a Spare Drive
To add a spare drive to an array, the array controller must have an attached drive that
is either unassigned or is assigned as a spare to another array. You can assign a spare
to as many arrays as you want, or you can assign a separate spare to each array.
When you select
Assign Spare
, only drives that qualify will be displayed (for
example, drives with too small a capacity will not be listed). If a drive that you
expect to see is not listed, press the
Tab
key to switch to the physical drive view and
check the capacity of the drive.
1.
In the
Logical Configuration View
panel, select the array that needs a spare, and
then press the
Enter
key.
2.
Select
Assign Spare
from the
Array Options
menu, and then press the
Enter
key.
3.
Select the drive that you want as the spare, and then press the
Enter
key.
4.
Press the
Esc
key to accept the new configuration and return to the
Main
Manual Configuration
screen.
Configuring the New Logical Drive
1.
In the
Logical Configuration View
panel, select the new logical drive that you
want to configure, and then press
Enter.
2.
Select
Fault Tolerance
in the
Logical Drive Options
menu, and then press the
Enter
key.
3.
Select the RAID level that you want, and then press the
Enter
key.
4.
Select
Stripe Size
and then press the
Enter
key.
5.
Select the stripe size that you want, and then press the
Enter
key.
6.
Press the
Esc
key to accept the settings, and return to the
Main Manual
Configuration
screen.
Configuring the Controller Settings
The
Controller Settings
menu option allows you to choose the drive rebuild priority,
expansion priority, and accelerator ratio for all arrays on the controller.