Configuring an Array
7-26
Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
COMPAQ CONFIDENTIAL
Writer: Amy L. Laffitte File Name: h-ch7 Configuring an Array
Codename: Executor Part Number: 266328-001 Last Saved On: 2/8/02 10:39 AM
3.
If your controller has a battery backed write cache, check the
Controller
Settings
screen to confirm that the write cache is enabled.
4.
Select the logical drive in the
Logical Configuration View
window.
5.
Click
Migrate
in the
Logical Drive
box.
6.
Change the RAID level by selecting the appropriate check box.
7.
Change the stripe size (Table 7-3 gives the optimum stripe size for specific
situations).
8.
Click
Done
to return to the
ACU Main Configuration
screen.
If you get a message stating that the number of sectors needs to be increased:
a.
Delete the old logical volume.
b.
Reconfigure the array as a new logical volume with the new fault-tolerance
method and stripe size that you had selected.
c.
Copy the backed-up data (from step 1) onto the new logical volume.
9.
To save the new settings, click
Controller
on the menu bar and select
Save
Configuration
.
Using CPQONLIN
The NetWare Online Array Configuration Utility (CPQONLIN) lets you configure
your drive arrays without shutting down your server. It also indicates when a drive
attached to the array controller has failed, is undergoing expansion, or is waiting
(queued) for expansion or rebuild.
To install CPQONLIN:
1.
Load CPQRAID.HAM from the SmartStart and Support Software CD or the
Controller Support Software CD and diskettes. (Detailed instructions are given in
the README file on the CD.)
2.
Load CPQONLIN.NLM from the same source.
3.
Open CPQONLIN.NLM and follow the on-screen instructions.