Table F-1: POST Error Messages
continued
Message
Description
Meaning and Recommended Action
1777
Slot x drive array –
ProLiant drive storage
enclosure problem
detected (followed by
one or more of the
following):
•
SCSI port (y):
Cooling fan
malfunction
detected
•
SCSI port (y):
Overheated
condition detected
•
SCSI port (y):
Side-panel must
be closed to
prevent
overheating
•
SCSI port (y):
Redundant power
supply
malfunction
detected
•
SCSI port (y):
Wide SCSI
transfer failed
•
SCSI port (y):
Interrupt signal
inoperative
•
Check SCSI
cables.
Check cooling fan operation by placing hand over
the fan. Check the internal plenum cooling fan in
tower servers or storage systems. If the fan is not
operating, check for obstructions and check all
internal connectors. Replace the unit side panel, if
it was removed.
When the ProLiant Storage System power LED is
amber instead of green, the following conditions
may be present:
•
A fan failure
•
A redundant power supply failure
•
A thermal problem
If the message directs you to check SCSI cables,
verify your cabling. If the cable routing is correct,
replace cables on the specified port until the POST
message is eliminated.
1778
Slot x drive array
resuming Automatic
Data Recovery
process.
No action required. This message appears
whenever a controller reset or power cycle occurs
while Automatic Data Recovery is in progress.