![Compaq DL360 - ProLiant - Photon Скачать руководство пользователя страница 109](http://html.mh-extra.com/html/compaq/dl360-proliant-photon/dl360-proliant-photon_user-manual_2645078109.webp)
POST Error Messages
Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
F-3
COMPAQ CONFIDENTIAL
Writer: Amy L. Laffitte File Name: o-appf POST Messages
Codename: Executor Part Number: 266328-001 Last Saved On: 4/18/02 2:47 PM
Table F-1: POST Error Messages
continued
Message
Description
Meaning and Recommended Action
1724
Slot x drive array –
physical drive position
change(s) detected –
logical drive
configuration has
automatically been
updated.
Logical drive configuration has been updated
automatically following physical drive position
changes. Press the
F1
key to resume.
1726
Slot x drive array –
array accelerator
memory size change
detected – array
accelerator
configuration has
automatically been
updated
This message is displayed if the controller is
replaced with a model that has a different amount
of cache memory.
1727
Slot x drive array –
new logical drive(s)
attachment detected (if
>32 logical drives, this
message will be
followed by
Auto-
configuration failed:
too many logical
drives
)
The controller has detected an additional array of
drives that was attached when the system was
powered down. The logical drive configuration
information has been updated to add the new
logical drives. The maximum number of logical
drives supported is 32—additional drives will not
be added to the configuration if this number is
exceeded. Press the
F1
key to resume.
1728
Slot x drive array –
abnormal shutdown
detected with write
cache enabled.
No array accelerator
battery backup on this
model array controller.
Any data that may
have been in array
accelerator memory
has been lost.
This message should never occur unless the write
cache is somehow enabled on a controller that
does not have batteries.
continued