Updating the Controller Firmware
5-6
Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
COMPAQ CONFIDENTIAL
Writer: Amy L. Laffitte File Name: f-ch5 updating the controller firmware
Codename: Executor Part Number: 266328-001 Last Saved On: 4/18/02 2:40 PM
SCU is provided on both the SmartStart and Support Software CD and the Smart
Array Controller Support Software CD. Compare the SCU version numbers from
these two sources and use the most recent version.
NOTE:
Before updating NetWare volumes or partitions, remember these tips to optimize
system performance:
•
If you want to use hardware-based RAID, do not select mirroring while using
INSTALL.NLM or NWCONFIG.NLM.
•
Novell recommends that you create volumes with a 64-kbyte block size to decrease the
amount of RAM required to mount the volume, and use the Block Sub-Allocation feature
to allow disk space to be allocated more efficiently.
•
Linear memory provides the best system performance in the NetWare environment. If you
previously used SCU to configure your server, this option would have been the default. To
check that the system is using linear memory, run SCU and view the Compaq memory
settings. Be sure that a linear option is selected under the
Base Memory
option.
1.
Restart the server from the CD.
2.
If the CD-ROM drive is bootable, go to step 5. Otherwise, locate the
CD-ROM
drive
:\SYSCFDSK\US directory, run the file QRST5.EXE, and follow the on-
screen instructions to create four SCU diskettes.
3.
Insert SCU diskette #1 into the server diskette drive.
4.
Restart the system.
5.
Select
System Configuration Utility
from the menu or list of icons that is
displayed.
6.
Follow the on-screen instructions to update or create and populate a system
partition.
7.
Exit from the SCU.
If the server does not reboot or a CD error message is displayed, press the
Ctrl+Alt+Del
keys to continue and reboot the server.