Mini-OTE 300 Installation Guide
All trademarks used in this publication are CommScope registered
201
9
CommScope Inc. All rights Reserved
77
10.5 CLOSING / SECURING CLOSURE
10.5.1 Apply optional routing label inside lid or on tray cover.
10
.5.2 Install port plugs into all unused ports. See photo 301.
10.5.3 Close lid. Ensure all port plugs, ground wire (if present) and cables are properly aligned.
Snap right side hinge, left side hinge, then top hinge. Hinges can be closed using
screwdriver
or
by hand.
See photos 302-304.
Lar
ge end of
por
t pl
ug
Photo # 301
10
.5.4 Tighten security bolt. See photo 305.
Photo # 3
0
2
Close right side 1st
Photo #
3
0
3
Close left side 2nd
Photo #
3
0
4
Close top last
Photo # 3
0
5
Note:
Tighten the security bolt
with a torque limiting tool, like a
type 216C can wrench (shown)
or 25 in.-lbs. maximum
Note:
To
assist in
closing the
right side
latch, the
top can be
pressed
closed and
the security
screw can
be started to
hold the top
closed.
Then, the
right side
latch can be
closed.
Caution:
Be sure
black braid or spiral
tubing is in place to
avoid pinching when
closing lid.