54
8.1.6 Wrap the 5” section of spiral wrap around ribbon so that it wraps around the ½” core tube. Secure each spiral
wrap to core tube with cable tie. Repeat on other side of sheath opening. See photos 192-193.
Note:
Straighten steel strength members back into original position
8.1.7 If cable is shielded and to be grounded, proceed to
Section 8.2
.
8.1.8 Proceed to
Section 8.3
to assemble cable retention hardware.
8.1.9 Snap cable retention assemblies into the appropriate locations. Secure with bolts if grounded. See photos
194-196.
8.1.10 Mark point of ribbon containing fibers to be spliced,51” from sheath opening where signal input comes from.
8.1.11 Remove ribbon containing fiber to be spliced from fiber stack. Store express fibers in storage area.
Tray stack
may be removed for easier access to storage. See photos 197-199.
8.1.12 Proceed to
section 8.4
for Fiber Routing and Splicing.
Mini-OTE 300 Installation Guide
All trademarks used in this publication are CommScope registered
201
9
CommScope Inc. All rights Reserved
Apply spiral wrap
Core tube
Photo # 192
Secure with cable tie
Photo # 193
Squeeze tab.
Lift up to
remove tray.
Squeeze
tab. Lift up
to remove
tray.
Photo #197
Photo #198
Storage
Store express fiber
Photo #199
Left
side entry port.
No ground
Snap into
cavity.
Photo #194
Right
side entry port.
No ground
Snap into
cavity.
Photo #195
Left side & Right side entry ports.
Ground bar & Inline bar installed
Snap into cavity