9.1.11 If ribbons are not to be spliced, route to storage area. Tray stack may be removed for easier access to storage.
See photos 236-239.
9.1.12 Proceed to
Section 9.4
, for Fiber Routing and Splicing.
9.2 CABLE & EXTERNAL GROUNDING
9.2.1 For cable with shielding, remove a
section of the outer sheath 180
⁰
around the cable by
1.0”
in length
measured from the end of the outer sheath in order to expose cable shielding. See photo 240.
1”
Photo #240
180
⁰
Squeeze
tab. Lift up
to remove
Squeeze
tab. Lift up
to remove
tray.
Photo #236
Storage
Photo #237
Photo #238
Photo #239
LEFT
side entry.
Ribbon storage.
Right
side entry.
Ribbon storage
NOTE:
Exposed
shielding will be
bonded to the cable
retention bracket and
ground bar.