Configuration via Web Interface
Commend SIP Series
54
2.0/0612
Reboot the SIP station
To reboot the station, click on the button
Reboot
.
User Accounts
In the section
User Accounts
the user settings can be administered:
Webuser Login:
Here the user name for the web interface login can be changed.
Webuser Password:
Here the password for the web interface login can be changed.
Remote control User Login:
Definition of a user name for remote access to the SIP station via
HTTP.
Remote control User Password:
Definition of a password for remote access to the SIP station via
HTTP.
Background Light
In the section
Background Light
the configuration of the backlight for the call buttons and label areas
of the SIP station can be carried out:
Active Level:
Configuration of the intensity of the backlight in active mode (e.g. while dialling a call
number) in 10 levels:
Minimum level “
1 (dimmest)
” to maximum level “
9 (brightest)
”.
If no modification of the backlight at activity shall take place, then “
0 (off)
” has to be selected.
Idle Level:
Configuration of the intensity of the backlight for idle state of the SIP station in 10 levels:
Minimum level “
1 (dimmest)
” to maximum level “
9 (brightest)
”.
If no modification of the backlight in idle state shall take place, then “
0 (off)
” has to be selected.
Idle Delay:
The time (in seconds) of inactivity is defined, after which the backlight illumination is
switched to idle mode (see above).
Link with Multifunction LED:
If the checkbox is activated, the behaviour of the backlight illumina-
tion is linked with the LED behaviour (
see page 41
). This means, as soon as the LED is on, also the
backlight for the call buttons and label areas is switched on; if the LED is blinking, also the backlight
will be blinking etc. (if e.g. an distinctive optical call indication is required, this function may be the
ideal solution).
Attention:
The dialogue for acknowledgement of the start of the download process is indicated 30 seconds after
the update button has been pressed.
The update button
may not
be
pressed
(again) during the active download!
Update
from
firmware
1.x to 2.0
: Settings like e.g. configuration of buttons (
”Phonebook Set-
tings”
are
not saved
!
Therefore it is recommended to carry out a
Factory Reset
after updating to firmware 2.0!
!! ATTENTION !!
During a
firmware update
the
power supply
of the SIP station
may not be disconnected under
any circumstances
– THIS CAN DAMAGE THE STATION!
The firmware update is completed with the reboot of the SIP station.
Note:
How to access the relay outputs by means of a “remote control user account” is described at
”Remote
Control”
.
Default: 8
Default: 0 (off)
Default: 30 seconds