32
Note that the standard
speed
of the VEDO control unit BUS is 38400 baud (see table 4).
The device address
must be unique and can only be programmed using dip switches (see table 3).
Addressing the BUS and setting its speed via dip switch
N°
DIP1
DIP2
DIP3 DIP4
1
OFF
OFF
OFF
OFF
2
ON
OFF
OFF
OFF
3
OFF
ON
OFF
OFF
4
ON
ON
OFF
OFF
5
OFF
OFF
ON
OFF
6
ON
OFF
ON
OFF
7
OFF
ON
ON
OFF
8
ON
ON
ON
OFF
9
OFF
OFF
OFF
ON
10
ON
OFF
OFF
ON
11
OFF
ON
OFF
ON
12
ON
ON
OFF
ON
13
OFF
OFF
ON
ON
14
ON
OFF
ON
ON
15
OFF
ON
ON
ON
16
ON
ON
ON
ON
BAUD
DIP5
DIP6
9600
OFF
OFF
38400
ON
OFF
57600
OFF
ON
115200
ON
ON
default
To access dip switch S1 and jumpers JP1 and JP2, you must remove the plastic
casing at the top.
Technical characteristics
Rated voltage
13.8 Vdc
Minimum input voltage
10.3 Vdc
Maximum input voltage
14.5 Vdc
Output voltage interval
10.3 - 14.5 Vdc
Consumption
40 mA (max)
Maximum output current
500mA
Operating temperature
-10°C/+40°C R.H. 75%
Dimensions [mm]
44x44x19 mm
Weight
50 g
Con
fi
guration jumpers
JP1
If activated, enables 485 BUS input terminal resistor*
JP2
If activated, enables 485 BUS output terminal resistor*
* Always remember to insert an end-of-line resistor between A and B of the 485 connection (using the relevant jumpers) to the two ends of the
main BUS line.
LED signals
DL1
Slow
fl
ashing:
no data transfer over BUS at the speed set using the dip switch.
Flashing quickly:
data transfer over BUS in progress.
DL2
Off:
the peripheral is communicating correctly;
Very slow
fl
ashing:
(approx. 3 seconds) no data package on the BUS.
BUS isolator terminal block
IN
B
RS485 data BUS for connection to Input B of the control panel serial line
A
RS485 data BUS for connection to Input A of the control panel serial line
24H
Tamper contact input
V-
Power supply negative input
V+
Power supply positive input
OUT
B
RS485 data BUS, detects operating anomalies around the output branch and intervenes by isolating the faulty or sabotaged branch.
Terminal B for peripheral input connection via BUS
A
RS485 data BUS, detects operating anomalies around the output branch and intervenes by isolating the faulty or sabotaged branch.
Terminal A for peripheral input connection via BUS
V-
Power supply negative output
V+
Power supply positive output
Tamper contact connection
The
24H
terminal needs the Tamper contact to be connected in single balanced con
fi
guration. A resistance
of
1.8K
Ω
, in series with the contact, is required.
In the event of V+ V- power supply shortage, the auto-reset fuse intervenes. For the reset to take place correctly, the power supply must be
cut off for one minute.
ALARM
SINGLE BALANCED
To guarantee system certi
fi
cation, the isolator must be positioned in boxes protected by an anti-opening switch, or in the control panel
housing. The 24h input must be connected to a balanced line.