11
Internal expansions
√
IMPORTANT: any operation involving the assembly or disassembly of expansion modules must be performed with all input power
(from power supply unit or battery) OFF, in order to avoid permanently damaging the expansion module you intend to add or
remove, as well as the switchboard card.
Telephone dialler functions (PSTN as standard)
• telephone line presence check
• number dialling, both pulse and DTMF
•
16 telephone numbers for voice calls and transmission of SMS, email and MMS (the latter three types are available only with the optional
GSM module).
• Contact ID compatible built-in digital dialler
• 4 telephone numbers for Contact ID
• con
fi
gurable test call
• override answering machine option
Messages and Voice Control expansion module (art. 30001303)
Optional, contains the part of the audio messages relating to the digital dialler, i.e. contains the audio messages to be sent on the standard or
GSM telephone line. Equipped with a plug-in connector for simpli
fi
ed
fi
tting.
The voice control section cannot be customised. It allows an authorised user to perform guided activation, deactivation, modi
fi
cation and status
checking operations on the system from a remote location, using a standard telephone or cellphone.
A second section is provided for the input of custom messages, in other words, all messages intended to provide speci
fi
c information about the
system. This information includes all data relating to alarm signalling (e.g. the data identifying the system address: "Home of Mr John Smith,
Queen Street, London").
The message expansion module does not initially contain any messages and must therefore be con
fi
gured (programmed by means of the
con
fi
guration software) at the time of
fi
rst installation. The same applies in the event of replacement of or addition to an existing system.
If this module is not
fi
tted, the only type of audio information that it will be possible to send by telephone is audio tones.
Audio module functions
• Up to 48 standard messages
• 16 freely usable messages (recording and transfer only from PC software)
• 6 service voice messages
• system management by means of interface with voice menu
• facility for activation, deactivation, output status modi
fi
cation and alarm reset from a remote location
Fitting the messages and voice control expansion module
√
First check that all power is OFF.
To
fi
t the message and voice control expansion module, simply plug it into connector MOD2. The module connector should plug into its counterpart
without requiring any force.
No auxiliary connection is required.