D E S C R I P T I O N
This Surface mounted PIR switch is suitable for mounting onto
a back box at least 16mm deep. Confi gurable for any room
occupancy style, via Time and Lux level adjusters. It switches
on the lighting load if the area is occupied and if the ambient lux
level is less than the chosen adjusted level (10 to 1000 lux). It
switches off the lighting load if the area is unoccupied for the set
time (up to 40 minutes). It is also suitable for non lighting loads
by setting the lux adjuster to the maximum point.
I N S TA L L AT I O N
To be installed by a competent person with reference to BS
7671. Make reference to the Precautions and Technical Details
sections overleaf. If in doubt consult a qualifi ed electrician.
• Plan where the PIR is to be located (see diagram 1).
Switch off supply and check for hidden cables and pipes.
Fix a suitable back box to the ceiling.
• The PIR should be connected as shown in diagram 2:
L - Live in. N - Neutral in. SL - Switched Line out.
• Secure the PIR onto the back box ensuring no wires are
trapped.
• Ensure the Time adjuster is set to minimum and Lux
to Photocell inactive (maximum), making reference to
diagram 3.
• Turn on the supply and any in-line switch (providing overide
off) and check the operation of the PIR.
O P E R AT I O N
When the power is switched on, the PIR will switch on the
lighting load for 1 minute then switch it off. After 3 seconds it will
switch on again if it detects movement and the room is deemed
dark enough. With Time set to minimum the load will stay on for
10 seconds so the detection range can be easily assessed.
Installation & Operating Instructions: AUT PIRSP
360º Ceiling Surface Mount PIR Switch
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
SL
Wall Switch
(Optional)
N
L
N
L
Load
230Vac
5A or 6A
MCB or
fuse
SL
L
N
L - Live in. N - Neutral in. SL - Switched Line out.
DIA
GRAM 2
DIA
GRAM 3
TIME SETTINGS
LUX SETTINGS
10 LUX
1000 LUX
PHOTOCELL
INACTIVE
40m
20m
10m
5m
2.5m
80s
10s
20s
40s
IN 002 AU
22/03/13
CEILING with PIR switch
5m Detection
at 2.4m ceiling height
DIA
GRAM 1
AUTOMATIC ENERGY CONTROL
TIME SETTINGS
LUX SETTINGS
10 LUX
1000 LUX
PHOTOCELL
INACTIVE
40m
20m
10m
5m
2.5m
80s
10s
20s
40s
Suggested typical wiring