10
Module connectors
Name
Function
MOD1
IP communication expansion module connection
MOD2
Messages and voice control expansion module connection
MOD3
Reserved
MOD4
Reserved
MOD5
GSM communication expansion module connection
Terminal block M1
Pin
Name
Function
1
Earth symbol
Connection for earthing the telephone line protection devices. Ensures their correct operation.
2
L1
Conductor 1 input from telephone line. Is connected directly to terminal TEL1
3
L2
Conductor 2 input from telephone line
4
TEL2
Conductor 2 output to telephone
5
TEL1
Conductor 1 output to telephone. Is connected directly to terminal L1
Terminal block M2
Pin
Name
Function
1
V+ BUS
Power supply positive for 485 communication bus. Limited to 1.35A
2
V-
Power supply negative All terminals marked V- are connected to each other
3
A
RS485 data bus - A
4
B
RS485 data bus - B
5
COM
Connection for alarm relay exchange switchboard pin (RY1)
6
NC
Normally closed connection for alarm relay (RY1). In standby the COM and NC terminals are kept closed together.
7
NO
Normally open connection for alarm relay (RY1). When the relay is attracted, the COM and NO terminals are kept closed together.
8
V+ SIR
Battery charge and power supply positive. Limited to 0.75A
9
TC2
Programmable block logic output. Permitted load 100mA. Polarity is determined by jumper JP5. If JP5 is set to OC, the output acts as an open collector: in
standby, it will not allow the passage of current, and if activated, it will close to earth. If JP5 is set to TC, however, in standby it will not allow the passage of current
and if activated, it will present a positive to the terminal.
10
TC1
As per TC1, but controlled by JP4
11
V-
Power supply negative
Terminal block M3
Pin
Name
Function
1
V+ AUX
Power supply positive for system sensors. Limited to 1.35A
2
I1
Programmable input zone 1.
3
I2
Programmable input zone 2.
4
V-
Inputs common / Power supply negative
5
I3
Programmable input zone 3.
6
I4
Programmable input zone 4.
7
I5
Programmable input zone 5.
8
I6
Programmable input zone 6.
9
V-
Inputs common / Power supply negative
10
I7
Programmable input zone 7.
11
I8
Programmable input zone 8.
12
V+ AUX
Power supply positive for system sensors. Electrically connected to terminal 1 of the same terminal block. Shares its limitation.
13
V-
Power supply negative
14
24H
Programmable anti-tamper input.
Indicator lights
Name
Function
DL1
Not present
DL2
Not present
DL3
Switchboard operating
DL4
Not present
DL5
Not present
Con
fi
guration jumpers
Name
Function
JP1
If activated, enables 485 bus terminal resistor
JP2
Reserved
JP3
Reset (closing it and then opening it restarts the programme)
JP4
TC2 polarity: Open Collector (OC) or Positive Command on TC (TC)
JP5
TC1 polarity: Open Collector (OC) or Positive Command on TC (TC)
JP6
Restore initial con
fi
guration (see installation paragraph)
JP7
Service input
Power supply connection
Name
Function
P1
PSU connector.