background image

36

Acquiring an RFID key code from the keypad

1. From the keypad, enter a valid installer code (default master code 001961).

2. Press 

Prog

3. The 

fi

 rst and second lines of the display will show the messages “Main Menu” and “Parameter Prog.” respectively, indicating that you can now 

modify the system options

4. Press the Con

fi

 rm key to enter the respective submenus

5. Using the navigation keys (up and down) select “ProximityKeys” submenu. Press Con

fi

 rm

6. The display will show the message “Key 1” and below it, the parameter that you can modify, namely “Description”

7. Using the navigation keys (left and right), select the number of the key you intend to acquire.

8. Press Con

fi

 rm if you intend to change the description, then con

fi

 rm to make the change or press C to leave the description as it is

9. Using the navigation keys (up and down), select the "Acquire"  submenu. Still using the navigation keys, select the type of peripheral from 

which you intend to acquire the key code and its bus address, then press Con

fi

 rm again

10.  The display will show the message “Acq. Key: In progress...”

11.  Bring the key close to the RFID reader: the message will change from "In progress..." to "Acquired"

12. Press Con

fi

 rm: the display will show a description of the colour of the key's plastic housing

13. Press Con

fi

 rm again to associate the key to the desired user.

14.  Once you have 

fi

 nished making changes from the keypad, remember to transfer them to the PC by means of the Comelit alarm switchboards 

con

fi

 guration programme.

Changing the date and time

 

To change the date and time from the keypad, you need to go into programming mode.

1. Go into programming mode as an installer (see relevant paragraph).

2. Using the navigation keys, select “System Mgmt.”, then continue as a user.

As installer:

1. Go into programming mode as a user (see relevant paragraph).

2. Using the navigation keys (up and down), select the “Options” menu on the second line of the display, and press Con

fi

 rm.

3. Using the navigation keys (up and down), select the “Change date/time” option on the second line, and press Con

fi

 rm.

4. The 

fi

 rst line will show DD-MM-YY (day, month and year) and the second line will display the date set on the switchboard.

5. Enter the date using the number keys (e.g. 1 September 2012 becomes 010912), then con

fi

 rm.

6. The 

fi

 rst line of the display now shows HH-MM (hours and minutes) and the second line shows the time set on the switchboard.

7. Enter the time in the format displayed (e.g. 1.15 pm becomes 1315), then con

fi

 rm.

8. This done, the display will show the message PARAMETER CHANGED.

9. Press C to go up one level in the menu, or C repeatedly until the date and time appear on the keypad.

As user:

Acquiring a radio sensor code from the keypad

1. Insert the battery in the sensor concerned and wait until the LED stops 

fl

 ashing. This applies to both magnetic contacts (REED) and infrared detectors 

(PIR)

2. From the keypad, enter a valid installer code (default master code 001961).

3. Press 

Prog

4. The 

fi

 rst and second lines of the display will show the messages “Main Menu” and “Parameter Prog.” respectively, indicating that you can now modify 

the system options

5. Press the Con

fi

 rm key to enter the respective submenus

6. Using the navigation keys (up and down), select “Radio Zones” submenu. Press Con

fi

 rm

7. The display will show the message “Radio Zone 1” and below it, the parameter that you can modify, namely “Description”

8. Using the navigation keys (left and right), select the position in which you intend to acquire the sensor

9. Using the navigation keys (up and down), select “Acquisition” and press Con

fi

 rm The display will show the message “Acq. Radio Zone: In progress...”

10.  Now press and release the tamper button on the sensor

11.  If acquisition is successful, the display will show the type of sensor (REED or PIR) and the unique code number of the sensor.

12.  If acquisition fails because the sensor is already saved on the switchboard, the display will show the message “Acq. failed Dev. Duplicated” In this 

case, it is preferable to acquire the parameters from a PC using the con

fi

 guration software, in order to check the programmed sensors, the acquired 

codes and their parameters. This will make it easier to correct any con

fi

 guration errors.

13.  Once you have 

fi

 nished making changes from the keypad, remember to transfer them to the PC by means of the Comelit alarm switchboards 

con

fi

 guration programme.

Содержание 30001008

Страница 1: ...EN TECHNICAL MANUAL www comelitgroup com VEDO system Technical Manual...

Страница 2: ...y reader art 30006003 18 Meaning of LEDs 18 Mounting and wiring the keypads 18 RFID proximity reader on bus art 30006104 19 Main features 19 Meaning of LEDs 19 Setting RFID reader speed 20 Addressing...

Страница 3: ...s 30 PSU connector 30 Tamper contact connection 30 Connecting V reference terminal 31 Earth connection 31 Art 30003106 technical specifications 31 BUS Isolator Art 30003105 31 Addressing the BUS and s...

Страница 4: ...e bus The system comprises a master unit the switchboard and a certain number of slave units the peripherals on the bus Regardless of system activation status the switchboard s task is to query the pe...

Страница 5: ...ote controls Radio 11 8 users 3 installers 38 32 users 6 installers 38 32 users 6 installers 56 50 users 6 installers 56 50 users 6 installers Keys Balance Type NO NC Single balancing Double balancing...

Страница 6: ...rance for operating the anti opening tamper correctly a presser element has been provided on the cover of the housing This element has a hole in it in which a self tapping screw can be inserted suppli...

Страница 7: ...switchboard is already assembled remove the electronic cards and the power supply unit from the bottom of the housing so as to avoid the risk of damage 1 1 2 If the input output expansion module is pr...

Страница 8: ...4 Route the cables through the respective holes 5 Fix the housing to the wall by tightening the screws fully home into the wall plugs but without damaging the housing mountings 6 You can now refit the...

Страница 9: ...ication of connections to switchboard terminals Switchboard card 30001008 30001034 30001068 The switchboard card is available in 3 versions with different features see the table on page 5 for details...

Страница 10: ...OC the output acts as an open collector in standby it will not allow the passage of current and if activated it will close to earth If JP5 is set to TC however in standby it will not allow the passage...

Страница 11: ...m a remote location using a standard telephone or cellphone A second section is provided for the input of custom messages in other words all messages intended to provide specific information about the...

Страница 12: ...ompletely Once you have fitted the module correctly connect the antenna to the respective connector IMPORTANT if the position of the switchboard does not allow the reception of an adequate GSM signal...

Страница 13: ...g of the LEDs on the IP GSM module The expansion card for GSM network communication is equipped with 5 indicator LEDs for giving information about device status and operation The LEDs are designated D...

Страница 14: ...fully into the connector then 2 release it the card will be pushed outwards so that you can grip it more easily To plug the memory card back into its connector simply insert the card into the connect...

Страница 15: ...each other in an ideal layout balance the line with the appropriate end of line resistor 120 ohm On some devices this resistor is installed on board and can be activated by means of a jumper or DIP sw...

Страница 16: ...nguish between the two sensors derives from the adoption of a balancing resistor 1 8K disposed in parallel to the contact of the first sensor to be monitored and a second balancing resistor 3 3K dispo...

Страница 17: ...freely configurable alarm inputs Main features Backlit 2 x 16 character LCD display initial software addressing from built in keypad Four LEDs for immediate indication of power ON battery alarm generi...

Страница 18: ...503 box 1 Position the base of the keypad with the fixing holes aligned with the two clips on the 503 box and using a pencil or marker pen mark the position of the hole for the anti tear bolt the bol...

Страница 19: ...with the Red LED active Slow flash System not activated and alarm sabotage or fault event memory present Fast flash System activated and alarm sabotage or fault event memory present Blue On Scenario...

Страница 20: ...with the RFID readers on bus on keypad on Safetouch on Minitouch or on Planux Manager they make it possible to activate and deactivate the system without any need for electrical contact An RFID key ca...

Страница 21: ...panel Optical tamper 485 bus interface for direct alarm interfacing Simplebus interface for home automation interfacing only with Minitouch Basic bridging from alarm to home automation facility for d...

Страница 22: ...ce you have made the necessary connections refit the display part to the frame first using the clips on the left hand side and then exerting slight pressure on the right hand edge to help join the rem...

Страница 23: ...rs on the top and two spring clips at the bottom There are also two safety screws to prevent accidental opening 1 4 1 3 3 2 Preparing the housing once you have opened the housing remove the electronic...

Страница 24: ...OFF 38400 ON OFF 57600 OFF ON 115200 ON ON N DIP1 DIP2 DIP3 DIP4 DIP5 DIP6 1 OFF OFF OFF OFF OFF OFF 2 ON OFF OFF OFF OFF OFF 3 OFF ON OFF OFF OFF OFF 4 ON ON OFF OFF OFF OFF 5 OFF OFF ON OFF OFF OFF...

Страница 25: ...contacts and or volumetric detectors and supervised wireless sirens to the switchboard Main features Up to 32 radio zones per module Up to 16 radio outputs including max 8 sirens Up to 8 radio sirens...

Страница 26: ...to 4 different frames captured at different times by the camera associated to the zone in alarm Network parameters of PAL IP module The PAL IP module must be correctly recognised by the switchboard b...

Страница 27: ...ctions the siren might sound only briefly but none of the switchboard functions logic operation GSM communication or communication to PSTN line will be influenced by the siren battery Connecting a non...

Страница 28: ...nd against battery inversion If the polarity of the battery is inverted a 10A fuse in the metal housing blows Connection to the switchboard is by means of a multiple pole connector whereas connection...

Страница 29: ...1 5A 2 Art 30076003 12V 7Ah 3 1 Art 30003106 Art 30002501 Plastic wall mounted housing for VEDO control panels Art 30002502 Metal wall mounted housing for VEDO control panels Art 30002503 Plastic flu...

Страница 30: ...t OUTPUTS O1 Open collector output 1 Programmed as module Anti Sabotage by default The output is active when module sabotage occurs O2 Open collector output 2 Programmed as module Low Battery Anomaly...

Страница 31: ...0076004 12V and 15Ah Features linked to the type of power supply unit connected to terminal J1 Power supply unit 30076101 30076102 30076103 Power supply unit type EN50131 6 TYPE A TYPE A TYPE A Input...

Страница 32: ...hing no data transfer over BUS at the speed set using the dip switch Flashing quickly data transfer over BUS in progress DL2 Off the peripheral is communicating correctly Very slow flashing approx 3 s...

Страница 33: ...modules and of the switchboard or alternatively bypass the anti tamper microswitches Remember that the anti tamper inputs can be configured only in double balance mode IMPORTANT upon first start up o...

Страница 34: ...ut the decimal point Modifying an alphanumeric string once you have selected the string to modify e g the description of a zone the first editable character will start flashing The characters can now...

Страница 35: ...he keypad confirms the action with the message DEACTIVATED 3 Deactivation will also deactivate any alarms in progress within a few seconds Muting an alarm with the system deactivated To mute an alarm...

Страница 36: ...show DD MM YY day month and year and the second line will display the date set on the switchboard 5 Enter the date using the number keys e g 1 September 2012 becomes 010912 then confirm 6 The first li...

Страница 37: ...7 The display will show the message Output 1 and below it the parameter that you can modify namely Description 8 Using the navigation keys left and right select the position in which you intend to ac...

Страница 38: ...Relay output 1 potential free exchange 3A 24VDC TC outputs Configurable as OC or OE limited to 100mA Setting the control panel to Service Status Exiting Service Status This function allows the install...

Страница 39: ...le with n structure for 0 22 mm2 the total resistance added by the cable becomes 17 ohm For connection to an alarm input 17 ohm does not generally compromise the performance of the system SHIELDED ALA...

Страница 40: ...it will be possible to buy a standard cable of suitable length but when this is not possible you will need to make the connection autonomously This is done using UTP CAT5 cable or higher The cable wil...

Отзывы: