Page | 55
TXF
Conveyor Belt Not Working
Reasons:
1.
No signal to Conveyor Belt
2.
Displayed error code in Servo driver
3.
Conveyor Belt Coupling is loose
Remedial Actions:
Case 1:
Loose connection in Servo Driver, Relay, Main Board, & PLC.
Case 2:
Check error code in the
Error Code Handling
section and take an action to resolve the error.
Case 3:
Tight the Conveyor Belt Coupling, as shown below:
Fig 75: Displaying the Conveyor Belt Coupling
Take-Up Not Working
Reasons:
1.
No signal to Take-Up Motor
2.
Take-Up motor movement is jammed
3.
Regulator is set at Low and Take-Up regulator not working
Remedial Actions:
Case 1:
Loose connection in Servo Driver and PLC.
Case 2:
Remove the Take-
Up roller and observe it’s movement.
Case 3:
Check the regulator settings and rotate the knob to ON it. Additionally, if regulator is not
working, replace it.