31
You are now ready to disassemble and clean your
freezer. Please refer to Part III – Initial Cleaning Pro-
cedure of this operation manual for instructions on
how to proceed.
!! IMPORTANT !!
You MUST disassemble the machine after draining
and follow the described cleaning and sanitizing
procedures as described in this operation manual in
order to maintain acceptable hygienic levels in your
product.
Part IX – Technical Information
A)
Refrigeration:
Compressor – Hermetic / Low Temperature
Suction Pressure (Cylinder) – 18-21 psig.
(Mix Tank) – 20-25psig.
Discharge Pressures – 250 to 260psig.
Refrigerant Type – R-404A ONLY
Cooling Type – Air or Water
Cylinder valve type – TXV w/equalizer
Mix tank valve type – AXV
Refrigerant Charge- See Machine Data Plate
B)
Beater / Auger Drive Motors
Motor Type – Leeson - ODP with C flange
Beater Rotation-(facing front of freezer)-CCW
H.O.T Amps – 7.0 single phase
Minimum Operating Voltage – 110vac.
Maximum Operating Voltage – 130vac.
C)
Thermal Overload
Overload Setting – 8.0 single phase
Overload Ranges – 7.5-11 amps – single phase
Thermal Overload – Calibrations and Settings
(Top View)
D)
Proximity Switch
The sensitivity of this switch can be adjusted
with a small screwdriver. The trimmer location
is on the switch body nearest the front panel. To
adjust, the adjustment screw should be turned
very carefully either in a clockwise direction to
increase the range or counter clockwise to
decrease the range of operation.
AMP.
CALIBRATION
ALWAYS IN
R POSITION
MAN AUT