![Coloelite UC-711 E Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/coloelite/uc-711-e/uc-711-e_operation-manual_2637563029.webp)
29
B) Pump Fed Machines
With frozen mix in the cylinder, select the Beater mode
on the front touch pad by pressing the Push to Select
button (#571.2) until pilot light #L4 illuminates. Allow
the machine to operate in the beater mode for 4 to 5
minutes. This will soften the product and allow for
easier product removal.
Place a pail under the dispensing head, holding it up
against the bottom of the head as high as possible and
slowly pull the dispensing handle. This will allow the
mix to drain from the machine.
After the frozen product is removed and liquid mix is
dispensing from the machine, press the Stop / Reset
button (#571.1) on the touch pad. Placing the machine
in the OFF mode, close both of the dispensing handles.
Slowly push in on the pressure relief plungers to
remove any remaining pressure from the cylinders.
Drain the remaining water and soap solution from the
freezer.
You are now ready to disassemble and clean your
freezer. Please refer to Part III – Initial Cleaning Pro-
cedure of this operation manual for instructions on
how to proceed.
!! IMPORTANT !!
You MUST disassemble the machine after draining
and follow the described cleaning and sanitizing
procedures as described in this operation manual in
order to maintain acceptable hygienic levels in your
product.
571.2
571.1