4.3 Connection diagrams BUS X101, X102
The buscable of the peripheral units is connected to the connectors X101 or X102. The cable
must be placed inside of the module rail to prevent interferences. Figure 16 shows the position
of the buscable connectors on the dispenser board:
Figure 16
Connector X102
Connector X101
Pin Signal
Pin Signal
Pin Signal
Pin Signal
1
+12V
2
+12V
1
GND
2
GND
3
READY
4
FEED
3
nc.
4
nc.
5
LSC
6
GSC1
5
nc.
6
nc.
7
TCY
8
nc.
7
nc.
8
TCY
9
nc.
10
nc.
9
GSC1
10 LSC
11 nc.
12
nc.
11
FEED
12 READY
13 GND
14
GND
13
+12V
14 +12V
4.4 Transformer wiring
The secondary side of the transformer is connected to the terminals X36...X39. Both
violet
wires are connected to the terminals signaled with a 7. Both
orange
wires are connected to the
terminals signaled with a 3. See also Figure 17:
Figure 17
X102
X101
1
1
1
2
13
14
1
2
14
13
X39
X36
3
3
7
7
violett
orange
5999.515-01E 12.06.2007 WM
Page 18 / 47