10 Testmode
The firmware of the Collamat 3600 has a standard test and diagnostic routine. If the DIL-switch
TEST is switched on while turning the power on, the firmware starts the test and diagnostics
routine. See also figure 24.
In the testmode, the motor is started and stopped periodically with the speed, set on the
SPEED potentiometer. If there are any labels threaded through the Collamat 3600, the labels
will be dispensed periodically.
In the testmode, the Collamat 3600 can be controlled by an ASCII-terminal or a PC with a ter-
minal emulation software. The communication with the Collamat will be done through the con-
nector X104 using the RS232 protocol. The test software is menu driven and self explaining.
The user language is English.
To communicate with a PC, a serial communication cable is used. The figure 33 shows the
electrical connections of the serial cable:
Figure 33
Communication parameters
Terminal settings
9600 Baud, 8 Bit, 1 Stop Bit, No Parity
TTY, Text
Figure 34 shows how to connect the Collamat 3600 to a PC:
Figure 34: Test connections
9 P o l D - S u b
1 0 P o l F l a c h k a b e l
3
5
9
2
3
5
1 0 p o l
1
1
GND
GSC1
+12V
GND
LSC
+12V
TCY
+12V
GND
RDY
FEED
IFD
IFD
+12V
GND
GSC2
+12V
GND
GSC3
NSTPI
NSTPO
GND
ERR
ERR
+12V
X 4 8
a 3
a 2
a 1
L 1
N 1
X46
9
6
1
F 1
2AT 230V
4AT 115V
N
L
X 5 1
F 2
2.5AT
1.6AT
F 3
3
3
7
7
I N
X 4 0
L
N
P E
X 1 0 1
X 1 0 2
1 2 V
5V
T E S T
DIR
D E L
NS
R 1
R 2
X104
1
2
R E S E T
FAULT
X61
X60
1
X 1 0 3
X 1 0 6
1
7
6
0
5
OUT
X1
X25
S P E E D
P R E D I S P
P O S
T C Y
X105
X39
X36
COM1
PC
Diagnosestecker
5999.515-01E 12.06.2007 WM
Page 31 / 47