4.2.3 Isolated output IFEED
This output is completely isolated to the electronic circuit of the labeler. Figure 13 shows the
schematic diagram of this isolated output:
Figure 13: Isolated output IFEED
4.2.4 Open-Collector-output IFEED
For better resistance against interferences, the Open-Collector-output
IFEED
is also equipped
with a photocoupler. Figure 14 shows the schematic diagram of the Open-Collector-output
IFEED
:
Figure 14: Open-Collector-outputs
4.2.5 Currentsource-output
For the IR-transmitter of the label scanner
TCY
, a controlled currentsource is used. Figure 15
shows the schematic diagram of the currentsource:
Figure 15: TCY-currentsource
PC355T
+
-
1n
1n
Umax.: 24 VDC
Imax: 25 mA
+5 V
PC355T
+
1n
Umax.: 24 VDC
Imax: 25 mA
+5 V
+12 V
TCY
4 IR-LEDs
OP-AMP
10k
100k
100n
10n
BCP54-16
100
LM358
PWM
H8/532
5999.515-01E 12.06.2007 WM