3.3 Adjustment of the optical label scanner
Figure 9
Proceeding of the adjustment of the optical label scanner:
Switch on the Collamat 3600. Set the label scanner potentiometer to zero. Pull the labelweb so
that the gap is located below the marking 1 of the scanner. Turn the potentiometer until the red
LED on the scanner goes off. Continue pulling the labelweb until a label is located below the
scanner. Continue turning the potentiometer until the LED switches off again. The optimum
setting is at the center position of the two potentiometer settings witch turned the LED off.
Remark:
If the setting of the optical label scanner is faulty, the gap between the labels
will not be detected. After the triggering of a labelling operation, the labeler
will stop after approx. 0.75 m of the labelweb.
For transparent labels, please use the mechanical label scanner.