background image

32  

Warranty

Cold Jet® (“CJ”) warrants its products (“Equipment”) provided under this Agreement to be free from defects in materials 
and workmanship for a period of 12 months (90 days on used equipment), under normal use, maintenance and service 
as stipulated in the Operator’s Manual, Commissioning, and Operator Training. At the discretion of CJ, failure to complete 

Installation, Commissioning, and Operator Training shall result in forfeit of warranty rights.  CJ warrants that the equipment 

will be in good working order on the Date of Shipment and will conform to CJ’s official published specifications.

The warranty period is 12 months (90 days for used equipment) for CJ manufactured Equipment. Original Equipment 
Manufacturers’ warranties provided by CJ on equipment purchased under this Agreement not manufactured by CJ will be 
passed through to the Buyer. The warranty period commences on the Date of Shipment of the Equipment.

CJ’s liability is limited to repairing or replacing, at its option, any covered part of its Equipment, which CJ has determined 
to be defective. Said repair or replacement will be made by CJ or its authorized representative free of charge to the 
Buyer during the warranty period.  Any replaced part will become the property of CJ. If, after repeated efforts, CJ is 
unable to restore its Equipment to good working order, or to replace the defective parts all as warranted, CJ may replace 
the Equipment in its entirety at its discretion. Any claim must be made in writing to CJ within 30 days after the defect is 
discovered and any claim not made within that period shall be deemed waived or released and denied. 

Warranty service provided under this Agreement does not assume uninterrupted operation of the Equipment. The 

suitability of the equipment for the purpose intended is not included in the warranty.

This warranty shall not apply and CJ shall be neither responsible nor liable for:

A.  Consequential, collateral or special losses or damages; 

B.  Equipment conditions caused by abnormal conditions of use, accident, neglect or misuse of Equipment, improper 

storage or damages resulting during shipment as determined by CJ;

C. 

The replacement of normal wear items, including but not limited to air, blast and whip end hoses;

D. 

Deviation from the Equipment’s prescribed maintenance programs, replacement parts, operating instructions, 
specifications or other terms of sale;

E.  Improper application of the product.

In no event shall CJ be liable for claims, whether arising from breach of contract or warranty claims of negligence or 

negligent manufacture, in excess of the purchase price.

THIS WARRANTY IS THE SOLE WARRANTY OF CJ AND ANY OTHER WARRANTIES, INCLUDING ANY WARRANTIES OF 

MERCHANTABILITY AND FITNESS FOR PARTICULAR USE, WHETHER EXPRESS OR IMPLIED BY LAW, FACT, COURSE OF 
DEALING, COURSE OF PERFORMANCE, USAGE OF TRADE, OR OTHERWISE, ARE HEREBY SPECIFICALLY EXCLUDED.

Содержание E-CO2 150

Страница 1: ...Original Instructions English January 2020 Dry Ice Blasting Abrasive E CO2 150 Operator Manual...

Страница 2: ...document is error free No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise...

Страница 3: ...iii Contents Introduction 1 Safety 3 E CO2 150 Description 10 Operations 13 Maintenance 31 Warranty 32 Technical Schematics 33 Contact Information 42...

Страница 4: ......

Страница 5: ...electronic mechanical magnetic or optical About the E CO2 150 The E CO2 150 combines a custom 1 5 cubic feet 42 5 liter pressurized pot with the following Cold Jet dry ice blasting machines Aero2 PLT...

Страница 6: ...7 kg 70964 001 Coarse Grade 2000 lb 907 2 kg 70965 001 Coarse Grade 4000 lb 1814 4 kg 70966 001 Medium Grade 50 lb 22 7 kg 70967 001 Medium Grade 2000 lb 907 2 kg 70968 001 Medium Grade 4000 lb 1814 4...

Страница 7: ...y ice is 109 F 78 9 C Avoid coming into direct contact with dry ice as it may cause severe tissue damage Study the material safety data sheet MSDS of dry ice CO2 supplied with the delivery of dry ice...

Страница 8: ...include yellow warnings triangles blue mandatory action circles or red prohibited action circles Symbol Definition General Warning Cold Temperature Warning Pressurized Material Ejection Hazards Electr...

Страница 9: ...ard in Place No Foreign Objects Allowed Inside Machine CO2 is in Use Protective Earth Ground Frame Chassis Terminal There may be other safety labels or warning signs on the machine that contain additi...

Страница 10: ...enance or attempt to open a Pressure Vessel for any reason while it is Pressurized ALWAYS Depressurize and properly disconnect equipment from its air source before performing any maintenance Do not mo...

Страница 11: ...NING Ensure adequate ventilation when operating this equipment to prevent the build up of CO2 gas If used indoors or other confined space a CO2 detector should be used to monitor for excessive unsafe...

Страница 12: ...rom abrasive material and the surface being blasted NEVER use abrasives containing high amounts of crystalline silica including silica sand beach sand and beryllium for abrasive blasting Airborne crys...

Страница 13: ...m x 15 m Blast Hose Extension 1 25 in x 50 ft 3 2 cm x 15 m Nozzle 7 7 16 in x 8 1 2 in 1 1 cm x 21 6 cm 6 3 8 in x 7 3 8 in 9 cm x 18 7 cm 5 5 16 in x 6 1 4 in 8 cm x 15 9 cm 4 1 4 in x 6 in 6 cm x 1...

Страница 14: ...y Choice of one abrasive blast nozzle Figure 1 Exhaust Air Valve and Muffler Blast Hose Connection Air Supply to Tank Valve Filter Separator with Manual Drain Pot Pressure Regulator Air Dry Ice Suppl...

Страница 15: ...11 E CO2 150 Recommended Components Figure 2 E CO2 150 Aero2 PLT 60 Overview Figure 3 E CO2 150 Operator with proper PPE...

Страница 16: ...s 4E0291 7 7 16 in x 8 1 2 in 1 1 cm x 21 6 cm 255 cfm 7 2 m m 100 psi 4E0290 6 3 8 in x 7 3 8 in 9 cm x 18 7 cm 200 cfm 5 7 m m 100 psi 4E0295 5 5 16 in x 6 1 4 in 8 cm x 15 9 cm 140 cfm 4 m m 100 ps...

Страница 17: ...0 Contact Cold Jet if any damage has occurred to the shipping container or the E CO2 150 see Contact Information on page 42 WARNING NEVER perform any maintenance or attempt to open the E CO2 150 in an...

Страница 18: ...d air source WARNING NEVER reach into the Pop up opening while filling the E CO2 150 It can close without warning causing severe injury or death WARNING NEVER use abrasives containing silica or beryll...

Страница 19: ...e supply hose The whip check should slip over the supply hose It may be possible that your hose or dry ice blaster has a different fitting if so it will be up to you to supply the correct fitting s Fi...

Страница 20: ...ool and freeze at the blaster feeder 2 Water ice may accumulate in the feeder distorting the air flow and seal 3 Water ice buildup may continue inside the blast hose to the nozzle 4 Media may clump 5...

Страница 21: ...ipment is present and being worn by all people in the vicinity of the E CO2 150 y Only personnel who have been thoroughly trained and have read and understand the Dry Ice Blaster operator manual are i...

Страница 22: ...When connecting the air supply hose to the blaster always run the hose through the choker of the whip check in case of accidental disconnect Figure 5 Whip Check Aero2 PLT 60 Connections Figure 6 Aero...

Страница 23: ...19 Aero C100 Connections Figure 7 Aero C100 Connections Aero 80FP Connections Figure 8 Aero 80FP Connections...

Страница 24: ...ings can now be connected at the control plate figure 9 Lastly the washer can be inserted and the nozzle can be screwed into the nozzle adapter at end of the blast hose Figure 9 Blast Hose Connection...

Страница 25: ...afety Pin Attaching the Blast Hose Figure 12 Dry Ice Only Abrasive Dry Ice Signal Hose Connections Connect the small signal hoses into the control side of the Abrasive Blaster There is only one way th...

Страница 26: ...small side down toward the blast hose as illustrated in figure 13 and not toward the nozzle or the nozzle connection may leak around the seal In order to activate the trigger to the nozzle the safety...

Страница 27: ...rasives containing silica WARNING NEVER stand near a E CO2 150 while it is in operation The release of the remote control handle will cause a sudden and violent release of compressed air from the exha...

Страница 28: ...ely installed in the blast hose nozzle holder The Dry Ice Blasting Abrasive System has the ability to blast with just dry ice It is recommended that the system be purged with air for 10 seconds before...

Страница 29: ...ety button on the side must be depressed and the handle compressed Make sure not to point the nozzle at anything or anyone that may be hurt or damaged Blast for 10 seconds or until water mist stops co...

Страница 30: ...ter out WARNING The E CO2 150 must be supplied with clean cool dry compressed air in order to function properly The included moisture separator on the E CO2 150 may not be sufficient to achieve this d...

Страница 31: ...ank Figure 18 E CO2 150 Ball Float On the Selector Plate toggle the switch down to the ABRASIVE DRY ICE position Figure 19 E CO2 150 Selector Plate When the switch is in this position the Dry Ice Blas...

Страница 32: ...sive flowing and you are sure the Pot has abrasive in it check to see that the toggle switch is in the ABRASIVE DRY ICE position If there is still no abrasive flowing make sure the Metering Valve is o...

Страница 33: ...8 cm Air cu ft min 80 90 100 115 125 140 190 230 m3 min 2 27 2 55 2 83 3 26 3 54 3 96 5 38 6 51 Power hp 17 20 25 27 28 30 36 60 kW 12 68 14 91 18 64 20 13 20 88 22 37 26 85 44 85 6 3 8 In 9 cm Air c...

Страница 34: ...Blowdown valve to ensure that there is no pressure in the system Disconnecting Air Supply Hose After the E CO2 150 has been depressurized and the inlet valve has been closed the compressed air supply...

Страница 35: ...hile it is pressurized The violent release of compressed air and propelled objects will cause serious injury or death Daily y Drain water out of the air filter before using the machine y Check the air...

Страница 36: ...to replace the defective parts all as warranted CJ may replace the Equipment in its entirety at its discretion Any claim must be made in writing to CJ within 30 days after the defect is discovered and...

Страница 37: ...33 Technical Schematics Pneumatic Schematics 34 39...

Страница 38: ...34...

Страница 39: ...35 C100 E CO2 150 Schematic...

Страница 40: ...36...

Страница 41: ...37 Aero 80FP E CO2 150 Schematic...

Страница 42: ...38...

Страница 43: ...39 PLT 60 E CO2 150 Schematic...

Страница 44: ......

Страница 45: ...____________________________________ ___________________________________________________________________ ___________________________________________________________________ ___________________________...

Страница 46: ...576 8981 Email soporte coldjet com Belgium Cold Jet bvba European Headquarters Zone 1 Researchpark 330 B 1731 Zellik Phone 32 0 13 53 95 47 After Hours Support 1 513 576 8981 Email service eu coldjet...