Installing In-Sight™ 1000 Series Vision Sensors
Section 3: Specifications
29
3.2 Detailed I/O Specifications
The In-Sight 1000 features one built-in acquisition trigger input and two configurable
discrete outputs for general-purpose use.
The number of I/O lines may be increased using the optional I/O Expansion Module,
which provides 8 additional discrete inputs and outputs.
3.2.1 Breakout Port Pin Assignments
Table 3-2 lists the pin assignment for each of the 8 signal lines of the In-Sight 1000
Breakout Port (labeled “24VDC”) according to each method of access.
Table 3-2: Breakout Port Pin Assignments
IN-SIGHT
BREAKOUT PORT PIN
SIGNAL
BREAKOUT CABLE
WIRE COLOR
BREAKOUT MODULE*
TERMINALS
EXPANSION MODULE*
TERMINALS
1
+24 VDC
White-Green
6, 8, 10, 12, 14, 15, 16
(+24V)
+24V
2 Trigger
+
Green
5
(TRG+)
TRG+
3 Trigger
–
White-Orange 4
(TRG-)
TRG-
4 Output
0
Blue
7
(OUT0)
HSOUT0
5 Output
1
White-Blue 9
(OUT1)
HSOUT1
6
Serial Receive
Orange
RS232 serial (9-pin D-
sub connector)
RS232 remote (9-pin D-
sub connector)
7
Serial Transmit
White-Brown
RS232 serial (9-pin D-
sub connector)
RS232 remote (9-pin D-
sub connector)
8
Ground
Brown
1, 2, 3 (GND)
GND
* Refer to the
In-Sight Breakout Module Installation and Reference
(P/N 597-0008-xx) and the I
n-Sight I/O Expansion Module
Installation and Reference
(P/N 597-0013-xx) for more detailed information.
Содержание In-Sight 1000
Страница 1: ...INSTALLING IN SIGHT 1000SERIES VISION SENSORS...
Страница 8: ......
Страница 14: ...Section 1 Introduction Installing In Sight 1000 Series Vision Sensors 6...
Страница 34: ...Section 2 Installing the In Sight 1000 Installing In Sight 1000 Series Vision Sensors 26...
Страница 46: ...Installing In Sight 1000 Series Vision Sensors www cognex com products InSight default asp P N 597 0001 03...