Section 2: Installing the In-Sight 1000
Installing In-Sight™ 1000 Series Vision Sensors
24
2.5.6 Host Name
The Host Name assigns a name, or “alias” for the In-Sight 1000 as it will appear when
browsing the network using the In-Sight PC Host.
Each In-Sight 1000 has its host name set automatically the first time it boots. The
format is “is1k
xxxxxx
”, where “
xxxxxx
” consists of the last 24 bits of the In-Sight 1000’s
unique MAC address. For example, an In-Sight 1000 with a MAC address 00-d0-00-06-
0b will be assigned the host name “is1k00060b”.
NOTE
The Host Name setting is not automatically assigned by the DHCP server (if used) or referenced
through the DNS server. If the Use DHCP Server checkbox is enabled and the DHCP server
supplies the Host Name, it is ignored in favor of the default host name or the name entered by
the user.
2.5.7 Domain
The Domain specifies the In-Sight 1000’s Fully Qualified Domain Name (FQDN) for the
network on which it is installed.
NOTE
When the Use DHCP Server check box is enabled, this field is grayed out and displays the value
assigned by the DHCP server.
An In-Sight 1000 sensor must have a FQDN to be accessible from a remote host that is
not part of the local network. The Domain setting sets the string that is appended to the
host name to make a FQDN.
For example, setting Domain to
yourcorp.com
yields the following results:
§
If a host name is system1, the FQDN for lookup is system1.yourcorp.com.
§
If a host name is
system1.yourcorp.com.
(note the period at the end), the
FQDN for lookup is
system1.yourcorp.com
.
Appending the period to the end of the host name prevents redundancy in appending
the Domain name to the FQDN. For example, if the period is omitted,
system1.yourcorp.com
would become
system1.yourcorp.com.yourcorp.com
.
Содержание In-Sight 1000
Страница 1: ...INSTALLING IN SIGHT 1000SERIES VISION SENSORS...
Страница 8: ......
Страница 14: ...Section 1 Introduction Installing In Sight 1000 Series Vision Sensors 6...
Страница 34: ...Section 2 Installing the In Sight 1000 Installing In Sight 1000 Series Vision Sensors 26...
Страница 46: ...Installing In Sight 1000 Series Vision Sensors www cognex com products InSight default asp P N 597 0001 03...