Section 2: Installing the In-Sight 1000
Installing In-Sight™ 1000 Series Vision Sensors
8
If you are connecting directly to an In-Sight sensor or In-Sight PC Host:
1
Plug one of the RJ-45 connectors on a CAT5 crossover cable into the ENET port
on the In-Sight 1000.
2
Plug the other end of the CAT5 crossover cable into the other system’s Ethernet
port.
2.1.2 Connecting the Breakout Cable
The In-Sight Breakout Cable (P/N 300-0340-15) included with every In-Sight sensor
provides access to the In-Sight 1000 sensor’s power, serial communications, and I/O
lines. The RJ-45 connector on this cable is “keyed” to the notch in the breakout port,
and cannot be inadvertently plugged in to the network port.
See Section 3.2.1: Breakout Port Pin Assignments on page 29 for the Breakout Cable’s
wiring details.
To connect the Breakout Cable to the In-Sight 1000:
1
Verify the 24VDC power supply being used is switched off.
2
Attach the Breakout Cable’s power (white-green wire) and ground (brown wire) to
the corresponding terminals on the power supply.
3
Connect the wires for the acquisition trigger, discrete outputs, and serial
communications to their corresponding terminals on remote devices.
4
Plug the RJ-45 connector into the In-Sight 1000 sensor’s breakout port (labeled
24VDC).
5
Restore power to the 24V supply. The green power LED will indicate that the 1000
is receiving power.
Содержание In-Sight 1000
Страница 1: ...INSTALLING IN SIGHT 1000SERIES VISION SENSORS...
Страница 8: ......
Страница 14: ...Section 1 Introduction Installing In Sight 1000 Series Vision Sensors 6...
Страница 34: ...Section 2 Installing the In Sight 1000 Installing In Sight 1000 Series Vision Sensors 26...
Страница 46: ...Installing In Sight 1000 Series Vision Sensors www cognex com products InSight default asp P N 597 0001 03...