- All Other Markets:
NOTE:
The burner operating pressure is to be measured at the manifold test point with both burners operating at
the 'High Flame' setting.
NAT, LPG & Butane Only - The operating pressure is ex-factory set and is not to be adjusted, apart from
when converting between gases, if required.
TOWN GAS Only - The burner operating pressure is to be adjusted using the adjustable gas regulator
supplied.
Refer to the ‘Gas Conversion and Specifications section of this manual for further details.
Main Burner Injectors
Ø 1.85mm
Ø 3.50 mm
Low Fire
Size
Ø 1.00mm
Ø 1.00 mm
Adjustment
2 turns out (c.c.w.)
4 turns out (ccw)
Supply Pressure
1.13 - 3.40 kPa
0.76 - 1.50 kPa
Burner Operating Pressure (*)
1.0 kPa (*)
0.63 kPa (*)
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to the Burner
Operating Pressure
specified)
Main Burner Injectors
Ø 1.85mm
Ø 1.10mm
Low Fire
Size
Ø 1.00mm
Ø 1.00mm
Adjustment
2 turns out (c.c.w.)
½ turn out (c.c.w.)
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
1.0 kPa (*)
2.55 kPa (*)
Gas Regulator Cap Screw