14
- NAT Gas / LPG / Butane Only.
NOTE:
The regulator supplied is convertible between
Natural Gas and LP Gas, but it’s outlet pressure is
fixed ex-factory and is NOT to be adjusted.
1. Ensure that the gas supply is turned 'Off' at the
mains.
2. Unscrew the hexagonal cap (23mm A/F) from
the regulator.
3. Un-clip the plastic pin from the cap, reverse the
pin and re-fit it back to the cap the correct way
for the gas type to be used.
(Either ‘LP’ or ‘NAT’
should be visible on the flank of the pin once
re-fitted to the cap)
.
4. Screw the cap back into the regulator hand
tight only.
- Town Gas Only.
1. Unscrew and remove slotted cap from regulator.
2. Turn ‘On’ the gas supply and the appliance.
3. Adjust pressure adjusting nut to achieve the
correct burner operating pressure.
NOTE:
The operating pressure is to be measured at the
manifold test point and with both burners operating
at the ‘High Flame’ setting.
4. Verify the operating pressure remains correct
(Re-adjust the regulator if required).
5. Screw the cap nut back onto the regulator.
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
Pressure Adjusting
Screw