5.  Lower the Salamander onto the mounting 

bracket. 

 

 
 
 
 
 
 
 
6.  Tighten the black spacers  

securely and adjust the  
levelling screws / bolts to  
ensure that the unit is level. 

 
 

NOTE: 
ALL  GAS  FITTING  MUST  ONLY  BE  CARRIED  OUT  BY  A 
QUALIFIED SERVICE PERSON. 

 
1.  Cobra salamanders do not require an electrical 

connection, as they function totally on the gas 
supply only. 

2.  It is essential that the gas supply is correct for the 

salamander to be installed and that adequate 
supply pressure and volume are available.  The 
following checks should therefore be made 
before installation:- 

a. 

Gas Type 

the appliance has been supplied 

for, is shown on a coloured stickers located 
above the gas connection and next to the 
rating plate.  Check that this is correct for the 
gas supply the appliance is being installed 
for.  The gas conversion procedure is detailed 
in this manual. 

b. 

Supply Pressure 

required for this appliance is 

shown in the ‘Specifications’ section of this 

manual.  Check the gas supply to ensure 
adequate supply pressure exists. 

c. 

Input Rate 

of this appliance is stated on the 

Rating Plate fitted to the R/H side panel and 
in the 'Specifications' section of this manual.  
The input rate should be checked against 
the available supply line capacity.  

Particular 

note should be taken if the salamander is 
being added to an existing installation.

 

 

NOTE: 
It  is  important  that  adequately  sized  piping  runs  
directly  to  the  connection  joint  on  the  appliance 
with  as  few  tees  and  elbows  as  possible  to  give 
maximum supply volume. 
 

NOTE: 
Only  non-combustible  materials  can  be  used  in 
close proximity to this appliance. 

We recommend allowing a clearance of 100 mm on 

either  side  of  the  appliance  to  allow  access  to 
the side panels for servicing purposes. 

**  Using  the  wall  mounting  accessories  provided 

with this appliance. 

*** Top clearances can be reduced where local fire 

protection  system  is  provided,  if  allowed  by  the 
local  regulations. 

 

1.  Fix the wall mounting bracket to the wall with six 

screws, in such a position that the top of the 
bracket is level and at least 945mm (38”) above 
any surface beneath the unit.  This will ensure 
that the bottom of the Salamander is at least 
600mm (24”) above any surface. 

2.  Fit the two black plastic spacers to the top rear 

corners of the unit.  Leave them unscrewed by 
approximately 5mm. 

3.  Fit the two adjusting screws / bolts into the  

nutserts at the bottom rear corners of the unit.  
These should protrude approximately 30mm from 
the rear of the Salamander. 

4.  Lift the Salamander onto the wall bracket, lining 

up the black plastic spacers on the salamander 
with the mounting notches in the bracket. 

 

~ 5 mm 

~30 mm 

 

 

LH / RH Side 

100 mm 

25 mm (*) 

Rear 

50 mm 

30 mm 

Top Clearance to: 
 

- Extraction Hood 

200 mm 

 

- Grease Arresting Filter (**) 

400 mm 

 

- Ceiling (***) 

750 mm 

Содержание CS9

Страница 1: ...Gas Salamander Model CS9 I N S T A L LA T I ON A N D OP E R A T I ON M A N U A L 242353 1 ...

Страница 2: ...00 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel 44 121 3...

Страница 3: ...es Wall Mounting To Non Combustible Wall Only Gas Connection Commissioning Operation Guide Description of Controls Lighting the Main Burners Racking System Cooking Recommendations General Racking Stainless Steel Surfaces Vitreous Enamel Surfaces Crumb Drip Tray Periodic Maintenance Gas Control Valve Re Greasing Gas Conversion Procedure Gas Specifications ...

Страница 4: ...ons for adapting the appliance to the conditions for use in that country IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATIO...

Страница 5: ...ntrols Each main burner is provided with flame failure feature for ease of operation and safety The main burners are manually lit with each burner having LO to HI settings to provide full cooking flexibility Rack supports have 4 fixed height positions offering flat and angled rack positioning Cobra Salamanders come standard with a crumb drip tray for collection of cooking grease and crumbs from th...

Страница 6: ...4 CS9 Gas Salamander ...

Страница 7: ...that this salamander is installed correctly and that operation is correct before use Installation shall comply with local gas and health and safety requirements Waldorf Salamanders are designed to provide years of satisfactory service and correct installation is essential to achieve the best performance efficiency and trouble free operation This appliance must be installed in accordance with Natio...

Страница 8: ...e salamander is being added to an existing installation NOTE It is important that adequately sized piping runs directly to the connection joint on the appliance with as few tees and elbows as possible to give maximum supply volume NOTE Only non combustible materials can be used in close proximity to this appliance We recommend allowing a clearance of 100 mm on either side of the appliance to allow...

Страница 9: ...e manifold test point with two burners operating at the High Flame setting NAT LPG Butane Only The operating pressure is ex factory set and is not to be adjusted apart from when converting between gasses if required TOWN GAS Only The burner operating pressure is to be adjusted using the adjustable gas regulator supplied Refer to the Gas Conversion and Specifications section of this manual for furt...

Страница 10: ...ration practices can reduce the life of the salamander and produce a poor quality product To use this salamander correctly please read the following sections carefully Lighting the Main Burners Racking System Cooking Recommendations The salamander has individual heat controls for the left and right sides Select the desired heat level and allow a few minutes for the elements to heat up Cobra salama...

Страница 11: ...randing Plate under the burners before cooking commences also allows the sealed in flavoured goodness to be achieved TO AVOID THE RISK OF FIRE DO NOT LEAVE THIS APPLIANCE UN ATTENDED WHEN IN USE AS IT DOES COOK FAST DO NOT USE OR PLACE ANY COMBUSTIBLE MATERIAL WITHIN 600MM OF THE FRONT COOKING ZONE WHEN THE APPLIANCE IS IN USE SYSTEMATICALLY CHECK AND CLEAN THE COOKING AREA PARTICULARLY THE GRILL ...

Страница 12: ...son If any small faults occur have them attended to promptly Don t wait until they cause a complete breakdown It is recommended that the appliance is serviced every 6 months Clean the salamander regularly A clean appliance looks better will last longer and will perform better For ease of cleaning of this unit and the racking system and to achieve the best results it is recommended that the racking...

Страница 13: ...es by pulling the knobs away from the control panel 2 Remove the crumb drip tray from the appliance 3 Remove the two screws on the underside of the control panel securing the control panel to the hob 4 Remove the control panel from the front of the appliance 5 Remove the 2 screws holding shaft plate to gas control body and remove control shaft and plate Note orientation of shaft for correct re ass...

Страница 14: ...eleasing knob before thermocouple has heated Main Burner flame too small Gas pressure too low Partially blocked main injector Thermocouple faulty Hold knob in for at least 20 seconds following ignition of main burner Call service provider Call service provider Main burners will not light No gas supply Incorrect supply pressure Blocked main injector Faulty gas control Ensure gas isolation valve is ...

Страница 15: ...fire adjustment Low fire screw on gas control valve should be screwed fully in then unscrewed by the measurement shown in the Gas Specifications table NOTE The Low Fire Screw should be sealed with coloured paint on completion of low fire adjustment Before leaving the converted installation 1 Check all gas connections for leakages using soapy water or other gas detecting equipment 2 Check the follo...

Страница 16: ...ble on the flank of the pin once re fitted to the cap 4 Screw the cap back into the regulator hand tight only Town Gas Only 1 Unscrew and remove slotted cap from regulator 2 Turn On the gas supply and the appliance 3 Adjust pressure adjusting nut to achieve the correct burner operating pressure NOTE The operating pressure is to be measured at the manifold test point and with both burners operating...

Страница 17: ...Ø 1 00mm Ø 1 00mm Adjustment 2 turns out c c w turn out c c w Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 1 0 kPa 2 55 kPa Gas Regulator Cap Screw Main Burner Injectors Ø 1 85mm Ø 1 15mm Low Fire Size Ø 1 00mm Ø 1 00mm Adjustment 2 turns out c c w turn out c c w Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 1 0 kPa 2 55 kPa Gas Regulator Cap Screw ...

Страница 18: ...o the Gas Conversion and Specifications section of this manual for further details Main Burner Injectors Ø 1 85mm Ø 3 50 mm Low Fire Size Ø 1 00mm Ø 1 00 mm Adjustment 2 turns out c c w 4 turns out ccw Supply Pressure 1 13 3 40 kPa 0 76 1 50 kPa Burner Operating Pressure 1 0 kPa 0 63 kPa Gas Regulator Cap Screw Adjustable Regulator Adjust to the Burner Operating Pressure specified Main Burner Inje...

Страница 19: ...d 230671 Thermocouple General 026096 Wall Mounting Bracket 013908 Spacer Foot Assy 017963 Rack 026093 Side Rack 227961 Screw Side Rack 231546 Crumb Drip Tray Accessories Optional 013418 Branding Plate XP UK only Gas Regulators Gas Conversion Kits IMPORTANT Only genuine qualified replacement parts should be used for the servicing and repair of this appliance The instructions supplied with the parts...

Страница 20: ......

Отзывы: