![Cobra CS9 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/cobra/cs9/cs9_installation-and-operation-manual_2630322017.webp)
15
- Australia:
- New Zealand:
- United Kingdom:
Category:
II
2H3P
(20, 30 / 37).
Flue Type:
A
1.
NOTE:
(*) Measure burner operating pressure at manifold test point with both burners operating at full setting.
Operating pressure is ex-factory set and is not to be adjusted, apart from when converting between
gases, if required. (Refer to details in this section for further information.
Main Burner Injectors
Ø 1.85mm
Ø 1.15mm
Low Fire
Size
Ø 1.00mm
Ø 1.00mm
Adjustment
2 turns out (c.c.w.)
½ turn out (c.c.w.)
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
1.0 kPa (*)
2.55 kPa (*)
Gas Regulator Cap Screw
Main Burner Injectors
Ø 1.85mm
Ø 1.15mm
Low Fire
Size
Ø 1.00mm
Ø 1.00mm
Adjustment
2 turns out (c.c.w.)
½ turn out (c.c.w.)
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
1.0 kPa (*)
2.55 kPa (*)
Gas Regulator Cap Screw
Main Burner Injectors
Ø 1.85mm
Ø 1.15mm
Low Fire
Size
Ø 1.00mm
Ø 1.00mm
Adjustment
2 turns out (c.c.w.)
½ turn out (c.c.w.)
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure (*)
10 mbar
26 mbar
Gas Regulator Cap Screw