background image

1.  Installation must allow for a sufficient flow of 

fresh air for the combustion air supply. 

 

Combustion Air Requirements 

Natural Gas   

9 m³/hr minimum. 

LPG / Butane  

9 m³/hr minimum. 

Town Gas 

 

9 m³/hr minimum. 

 
2.  Installation must include adequate ventilation 

means, to prevent dangerous build up of  
combustion products. 

3.  This appliance must be mounted onto a non-

combustible wall or tailored stand, using the rear 
wall bracket and spacing screws provided. 

4.  Combustible walls must not protrude past the 

front of the appliance. 

5.  This appliance must not be mounted on a  

combustible surface or metal surface, as  
radiated heat will cause these surfaces to  
become extremely hot. 

6.  Caution should be taken as intense heat is  

emitted at the bottom front of the appliance. 

7.  Components having adjustments protected 

(e.g. paint sealed) by manufacturer are only to 
be adjusted by an qualified service agent. They 
are not to be adjusted by the installation person. 

8.  The unit should be mounted under an extraction 

hood in compliance with all local regulations. 

 

In the event that the unit is not mounted under an 

extraction hood, the installer must ensure that all 

regulations are met and that there is an  

unobstructed minimum distance of 750mm from the 

top surface of the unit to the ceiling, which must be 

of non-combustible material. 

 

NOTE: 
Do not obstruct or block the appliances flue.  Never 
directly  connect  a  ventilation  system  to  appliance 

flue outlet. 

NOTE: It  is  most  important  that  this  salamander  is 
installed  correctly  and  that  operation  is  correct 
before use.  Installation shall comply with local gas 
and health and safety requirements. 

 
Waldorf Salamanders are designed to provide years 

of satisfactory service, and correct installation is 
essential to achieve the best performance,  
efficiency and trouble-free operation. 

This appliance must be installed in accordance with 

National installation codes and in addition, in  
accordance with relevant National / Local codes 
covering gas and fire safety. 

 

Australia: 
 

AS 5601 - Gas Installations. 

New Zealand: 

 

NZS 5261 - Gas Installation. 

 

Installations must be carried out by qualified service 

persons only.  Failure to install equipment to the  
relevant codes and manufacturer’s specifications 
shown in this section will void the warranty. 
Components having adjustments protected (e.g. 

paint sealed) by the manufacturer, are only to be 
adjusted by an qualified service agent.  They are 
not to be adjusted by the installation person. 

 

 

 

Remove all packaging and transit protection 
from the appliance including all protective 
plastic coating from the exterior stainless steel 
panels. 

 

Check equipment and parts for damage.  
Report any damage immediately to the carrier 
and distributor. 

 

Report any deficiencies to the distributor who 
supplied the appliance. 

 

Check that the available gas supply is correct to 
that shown on the rating plate located on the 
front lower corner of the right hand side panel. 

 

Check that the following parts have been 
supplied with the appliance:- 

1 x Salamander Rack. 

1 x Trough Tray. 

1 x Gas Regulator. 

1 x Gas Conversion Kit. 

1 x Wall Mounting Bracket, including; 

- 2 x 25 mm Black Plastic Spacers. 

Содержание CS9

Страница 1: ...Gas Salamander Model CS9 I N S T A L LA T I ON A N D OP E R A T I ON M A N U A L 242353 1 ...

Страница 2: ...00 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel 44 121 3...

Страница 3: ...es Wall Mounting To Non Combustible Wall Only Gas Connection Commissioning Operation Guide Description of Controls Lighting the Main Burners Racking System Cooking Recommendations General Racking Stainless Steel Surfaces Vitreous Enamel Surfaces Crumb Drip Tray Periodic Maintenance Gas Control Valve Re Greasing Gas Conversion Procedure Gas Specifications ...

Страница 4: ...ons for adapting the appliance to the conditions for use in that country IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATIO...

Страница 5: ...ntrols Each main burner is provided with flame failure feature for ease of operation and safety The main burners are manually lit with each burner having LO to HI settings to provide full cooking flexibility Rack supports have 4 fixed height positions offering flat and angled rack positioning Cobra Salamanders come standard with a crumb drip tray for collection of cooking grease and crumbs from th...

Страница 6: ...4 CS9 Gas Salamander ...

Страница 7: ...that this salamander is installed correctly and that operation is correct before use Installation shall comply with local gas and health and safety requirements Waldorf Salamanders are designed to provide years of satisfactory service and correct installation is essential to achieve the best performance efficiency and trouble free operation This appliance must be installed in accordance with Natio...

Страница 8: ...e salamander is being added to an existing installation NOTE It is important that adequately sized piping runs directly to the connection joint on the appliance with as few tees and elbows as possible to give maximum supply volume NOTE Only non combustible materials can be used in close proximity to this appliance We recommend allowing a clearance of 100 mm on either side of the appliance to allow...

Страница 9: ...e manifold test point with two burners operating at the High Flame setting NAT LPG Butane Only The operating pressure is ex factory set and is not to be adjusted apart from when converting between gasses if required TOWN GAS Only The burner operating pressure is to be adjusted using the adjustable gas regulator supplied Refer to the Gas Conversion and Specifications section of this manual for furt...

Страница 10: ...ration practices can reduce the life of the salamander and produce a poor quality product To use this salamander correctly please read the following sections carefully Lighting the Main Burners Racking System Cooking Recommendations The salamander has individual heat controls for the left and right sides Select the desired heat level and allow a few minutes for the elements to heat up Cobra salama...

Страница 11: ...randing Plate under the burners before cooking commences also allows the sealed in flavoured goodness to be achieved TO AVOID THE RISK OF FIRE DO NOT LEAVE THIS APPLIANCE UN ATTENDED WHEN IN USE AS IT DOES COOK FAST DO NOT USE OR PLACE ANY COMBUSTIBLE MATERIAL WITHIN 600MM OF THE FRONT COOKING ZONE WHEN THE APPLIANCE IS IN USE SYSTEMATICALLY CHECK AND CLEAN THE COOKING AREA PARTICULARLY THE GRILL ...

Страница 12: ...son If any small faults occur have them attended to promptly Don t wait until they cause a complete breakdown It is recommended that the appliance is serviced every 6 months Clean the salamander regularly A clean appliance looks better will last longer and will perform better For ease of cleaning of this unit and the racking system and to achieve the best results it is recommended that the racking...

Страница 13: ...es by pulling the knobs away from the control panel 2 Remove the crumb drip tray from the appliance 3 Remove the two screws on the underside of the control panel securing the control panel to the hob 4 Remove the control panel from the front of the appliance 5 Remove the 2 screws holding shaft plate to gas control body and remove control shaft and plate Note orientation of shaft for correct re ass...

Страница 14: ...eleasing knob before thermocouple has heated Main Burner flame too small Gas pressure too low Partially blocked main injector Thermocouple faulty Hold knob in for at least 20 seconds following ignition of main burner Call service provider Call service provider Main burners will not light No gas supply Incorrect supply pressure Blocked main injector Faulty gas control Ensure gas isolation valve is ...

Страница 15: ...fire adjustment Low fire screw on gas control valve should be screwed fully in then unscrewed by the measurement shown in the Gas Specifications table NOTE The Low Fire Screw should be sealed with coloured paint on completion of low fire adjustment Before leaving the converted installation 1 Check all gas connections for leakages using soapy water or other gas detecting equipment 2 Check the follo...

Страница 16: ...ble on the flank of the pin once re fitted to the cap 4 Screw the cap back into the regulator hand tight only Town Gas Only 1 Unscrew and remove slotted cap from regulator 2 Turn On the gas supply and the appliance 3 Adjust pressure adjusting nut to achieve the correct burner operating pressure NOTE The operating pressure is to be measured at the manifold test point and with both burners operating...

Страница 17: ...Ø 1 00mm Ø 1 00mm Adjustment 2 turns out c c w turn out c c w Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 1 0 kPa 2 55 kPa Gas Regulator Cap Screw Main Burner Injectors Ø 1 85mm Ø 1 15mm Low Fire Size Ø 1 00mm Ø 1 00mm Adjustment 2 turns out c c w turn out c c w Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 1 0 kPa 2 55 kPa Gas Regulator Cap Screw ...

Страница 18: ...o the Gas Conversion and Specifications section of this manual for further details Main Burner Injectors Ø 1 85mm Ø 3 50 mm Low Fire Size Ø 1 00mm Ø 1 00 mm Adjustment 2 turns out c c w 4 turns out ccw Supply Pressure 1 13 3 40 kPa 0 76 1 50 kPa Burner Operating Pressure 1 0 kPa 0 63 kPa Gas Regulator Cap Screw Adjustable Regulator Adjust to the Burner Operating Pressure specified Main Burner Inje...

Страница 19: ...d 230671 Thermocouple General 026096 Wall Mounting Bracket 013908 Spacer Foot Assy 017963 Rack 026093 Side Rack 227961 Screw Side Rack 231546 Crumb Drip Tray Accessories Optional 013418 Branding Plate XP UK only Gas Regulators Gas Conversion Kits IMPORTANT Only genuine qualified replacement parts should be used for the servicing and repair of this appliance The instructions supplied with the parts...

Страница 20: ......

Отзывы: