Restart
Turns all active lasers ON by re-starting the autostart sequence.
Abort
Turns all lasers OFF.
Active
Check the box to choose the lasers that are active in the autostart sequence.
ON/OFF
Use these buttons to toggle the individual laser lines ON and OFF after the autostart sequence has
been completed.
Commands
Opens a command communications window to send commands directly to the laser. See section
10.3 :
Communication commands
for more details on available commands.
Message
Highlights important information about the laser status to the user.
Disconnect
Allows the user to disconnect from the Cobolt Monitor™ software in a controlled way.
NOTE
The communication cable should not be removed when the software is in connect state. To
disconnect the laser click “Disconnect” or close Cobolt Monitor™ completely. It is also possible to disconnect
by powering the laser OFF. In this case Cobolt Monitor™ will automatically close the window for that laser.
More
An additional Cobolt Monitor™ window will open containing more detailed information of that
laser’s status.
!