Autostart Program
- displays whether the laser is in CDRH or OEM mode and displays the current laser operational
status. There are a
lso buttons to “abort” the autostart sequence or to “restart” the laser after a fault.
NOTE
Specifications are only guaranteed in constant current mode, at 100% of nominal power.
Fault Status
–
displays ERROR messages. In the event of an ERROR, the laser action is stopped. When the reason for
the ERROR event is understood and the problem is addressed the fault status can be cleared with “Clear Fault”. If the
Autostart Program is enabled, click restart to restart the laser.
LED Status
- displays the LEDs that are currently illuminated on the key control box, see section 4.3.These are
displayed even if the laser is in OEM mode.
POWER
Green
Power is supplied.
ON
Orange
Laser emission is on. This light is on in modulation mode if laser emission is possible.
ERROR
Red
An error has occurred.
!