15
IR REMOTE CONTROL ADDITIONAL INFORMATION
When programming an incorrect address code for example 32 when there are
only 3 units connected it will just be ignored / nothing will happen if either the
up-arrow & down-arrow keys are then pressed. Wait 5 seconds and re enter
the correct address code.
During initial programming of the cable height the Up & Down buttons work on
a press and hold basis, where the microphone will continue to move either up
or down all the time the button is pressed. The cable will stop when either
button is released.
If there is a pause of longer than 5 seconds between button pressing before
the ENTER button is pressed the sequence will need to be started again from
the beginning. Once the green programme led is lit there is no time out limit.
A green led will light on the IR sensor to indicate that programme mode has
been entered. The led will extinguish when you exit the programme mode
(press Enter). Thereafter each time a remote button is pressed a red led will
flash indicating a command has been received and the transmitter is in range.
IR range is approx. 25 feet (7.5M). Do not use the IR remote control if a DSP
is being used to operate the Retracta. Only use the IR remote for setting the
height after installation.
Do not mix IR and DSP operation together. i.e. when microphones are at the
ceiling bezel if IR is used to deploy the microphones then the IR must be used
to retract the microphones. If the microphone is at the ceiling bezel and DSP
is used to deploy the microphones then the DSP must be used to retract the
microphones.