12
Master Unit Cable Wiring Connections using a DSP
1. Connect socket (3) to the DSP making sure that all parameters are met in
accordance to the instructions shown under “Mute Control” and Logic Hi /Lo
2.5V
– 12V required for activation.
2.
Connect the XLR microphone audio output to DSP audio input. If connected
to a mixer then the mute will not be detected and the microphone will always
be live. The DSP is used to mute the microphone.
Note Phantom power
must be supplied to the XLR microphone socket.
Termination Impedance (Z switch)
On each of the units is a slide
switch “Z” In a multi system 10 or more units it is only
the final slave unit that needs to have this switch ON and all other units switches
must be OFF.
On
Off
IR SENSOR INSTALLATION
Mount the IR sensor in a position (ceiling or wall) where it will be convenient to see
all the Retracta movements whilst maintaining good line of site with the IR sensor.
Do not place any obstruction in front of the sensor as this will prevent operation. Drill
a (16mm) (5/8") diameter hole. Pass the sensor through the hole and secure it using
the C clip. Connect the cable to the IR sensor input socket number 1 on the
Retracta unit.
IR sensor has 2 coloured led’s: Green = In programme mode, Red =
will show each time a button is pressed on the remote.