13
Slave wiring connections
When adding a second Retracta unit (slave 01)
1. Connect a DC supply cable between the Master and slave DC input sockets.
Make sure that the correct polarity is applied to the Phoenix plug supplied
Positive (+)
Negative (-)
2. Connect socket (4) on the master to socket (3) on the slave unit using an
RJ45 straight through cable. (if further slaves are connected then link between
socket (4) and socket (3) of the next slave and so on (daisy chain).
3. Bezel cable . Connect the cable to socket (2) on the slave.
4. Connect the DSP microphone audio input to the XLR audio out socket.
5.
Make sure that the “Units” decimal rotary switch is set to “1” (01)
Further Slave wiring connections
1. Up to 99 Slaves can be linked together in the same / identical way as
described above un
der “adding a second cable Retracta”.
2 Repeat the same instructions shown under heading of Slave wiring
connections and link between / daisy chain between sockets 3 and 4 of each
slave unit.
3 Make sure that the
“Units” decimal rotary switch on each subsequent slave
units are set to
“2” for the 2nd slave, “3” for the 3rd slave etc etc....