EXCELLENCE VERSION
Acoustic configuration: compressor soundproofing (SC)
General technical data - Construction
Size
260.6
280.6
300.6
320.6
340.6
360.6
400.8
440.8
480.8
Compressor
Type of compressors
-
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
No. of compressors
Nr
6
6
6
6
6
6
8
8
8
Rated power (C1)
[HP]
120
140
140
160
160
180
100
100
120
Rated power (C2)
[HP]
140
140
160
160
180
180
100
120
120
Rated power (C3)
[HP]
-
-
-
-
-
-
100
100
120
Rated power (C4)
[HP]
-
-
-
-
-
-
100
120
120
Std Capacity control steps
-
11
12
13
14
11
6
12
10
8
Oil charge (C1)
[l]
19
19
19
19
19
19
13
13
13
Oil charge (C2)
[l]
19
19
19
19
19
19
13
13
13
Oil charge (C3)
[l]
-
-
-
-
-
-
13
13
13
Oil charge (C4)
[l]
-
-
-
-
-
-
13
13
13
Refrigerant charge (C1)
1
[kg]
69
71
91
92
92
107
54
55
65
Refrigerant charge (C2)
1
[kg]
71
71
92
92
107
107
53
61
63
Refrigerant charge (C3)
1
[kg]
-
-
-
-
-
-
54
55
65
Refrigerant charge (C4)
1
[kg]
-
-
-
-
-
-
53
61
63
Refrigeration circuits
-
2
2
2
2
2
2
4
4
4
Internal exchanger
Type of internal exchanger
2
-
PHE
PHE
PHE
PHE
PHE
PHE
PHE
PHE
PHE
Number of internal exchangers
Nr
2
2
2
2
2
2
2
2
2
Total water content
[l]
65,0
74,0
79,0
84,0
87,0
90,0
98,8
115,4
123,8
Minimum system water content
3
l
1824
1365
1766
2345
1990
1753
1973
2575
3498
External Section Fans
Type of fans
4
-
AX
AX
AX
AX
AX
AX
AX
AX
AX
Number of fans
Nr
12
12
16
16
16
16
20
20
20
Type of motor
5
-
AC/P
AC/P
AC/P
AC/P
AC/P
AC/P
AC/P
AC/P
AC/P
Standard airflow
[l/s]
73120
72035
97494
96046
95118
94191
116663
115405
114147
Connections
Water fittings
-
6”
6”
6”
6”
6”
6”
8”
8”
8”
Power supply
Standard power supply
V
400/3~/50
400/3~/50
400/3~/50
400/3~/50
400/3~/50
400/3~/50
400/3~/50
400/3~/50
400/3~/50
Power line
Nr
2
2
2
2
2
2
2
2
2
Electrical data
F.L.A. -Power line 1
[A]
246,2
286,4
294,6
334,8
334,8
375,0
416,9
457,1
497,3
F.L.I. - Power line 1
[kW]
151,4
174,8
178,5
201,9
201,9
225,3
252,4
275,8
299,2
F.L.A. - Power line 2
[A]
286,4
286,4
334,8
334,8
375,0
375,0
416,9
457,1
497,3
F.L.I. - Power line 2
[kW]
174,8
174,8
201,9
201,9
225,3
225,3
252,4
275,8
299,2
M.I.C. - Value
6
A
802,3
842,4
899,0
939,2
979,4
1019,6
1103,5
1183,9
1264,3
M.I.C. - with soft start accessory
6
A
802,3
842,4
899,0
939,2
979,4
1019,6
1103,5
1183,9
1264,3
1. Indicative values for standard units with po/-10% variation. The actual data are indicated on the unit label
2. PHE = plate exchanger
3. The minimum system water content calculated value does not consider the internal exchanger water content (evaporator). With outdoor air low temperature applications or low medium requested loads, the minimum installation water
volume is obtained doubling the indicated value.
4. AX = axial fan
5. AC/P = asynchronous three-phase external rotor motor with phase cutting speed automatic control
Unbalance between phase max 2 % Voltage variation: max +/- 10%
Electrical data refer to standard units; according to the installed accessories, the data can suffer some variations.
6. M.I.C.=Maximum unit starting current.
The M.I.C. value is obtained adding the max. compressor starting current of the highest size to the power input at max. admissible conditions (F.L.A.) of the remaining electric components.
M08T40D16-02
WSAT-XSC3 260.6-480.8
61
Содержание WSAT-XSC3 260.6-480.8
Страница 46: ...46 WSAT XSC3 260 6 480 8 M08T40D16 02 8 16 Compressor replacement ...
Страница 47: ...M08T40D16 02 WSAT XSC3 260 6 480 8 47 8 17 Exchanger replacement 8 18 Pump replacement ...
Страница 49: ...M08T40D16 02 WSAT XSC3 260 6 480 8 49 ...
Страница 50: ...50 WSAT XSC3 260 6 480 8 M08T40D16 02 ...
Страница 75: ...Page intentionally left blank M08T40D16 02 WSAT XSC3 260 6 480 8 75 ...