85
NOTE
If YES is selected in HEAT MODE ,the installation of
additional heating source should follow on the chapter
Typical applications - 5a or 5b.
If YES is selected in DHW MODE, the installation of
additional heating source should follow on the chapter
Typical applications - 5c.
HOLIDAY AWAY setting
When the cursor is on T4_AHS_ON, dT1_AHS_ON,
dT1_AHS_OFF or t_AHS_DELAY, use LEFT RIGHT and UP
DOWN to scroll and adjust the parameter.
T4_AHS_ON is the ambient temperature for starting the
additional heating source. When the ambient temperature
rises above T4_AHS_ON, the additional heating source will
be unavailable.
The relationship between the operation of additional heating
source and ambient temperature is shown in the picture
below:
When the cursor is on T1S_H.A._H or T5S_H.M_DHW, use
LEFT RIGHT and UP DOWN to scroll and adjust the
parameter, T1S_H.A._H is the target outlet water temperature
for space heating when in holiday away mode.
T5S_H.M_DHW is the target outlet water temperature for
domestic hot water heating when in holiday away mode.
dT1_AHS_ON is the temperature difference between T1S and
T1B for turning the additional heating source on(only when
T1B<T1S-dT1_AHS _ON will the unit turn on),
dT1_AHS_OFF is the temperature difference between T1S
and T1B for turning the additional heating source off (when
T1B
≥
T1S+dT1_AHS_OFF the additional heating source will
turn off), t_AHS_DELAY is the time that the compressor has
run before starting the additional heating source.
It should be shorter than the additional heating source start
time interval.
The operation of the heat pump and the additional heating
source is shown below:
If solar energy kit is installed, please select YES at “7.3
SOLAR ENERGY”, then the solar pump will operate when the
solar energy kit operating for domestic hot water heating, and
the heat pump will stop operating for domestic hot water
heating.
About setting
The HOLIDAY AWAY SETTING is used to set the outlet water
temperature to prevent freezing when away for holiday..
How to enter the setting
To enter the HOLIDAY AWAY SETTING, go to MENU > FOR
SERVICEMAN > HOLIDAY AWAY SETTING.
Press OK.
The following page is displayed:
Service call setting
The installers can set the phone number of the local dealer in
SERVICE CALL.
If the unit doesn’t work properly, call this number for help.
Configuration
To set the SERVICE CALL, go to MENU > FOR
SERVICEMAN > SERVICE CALL. Press OK.
The following page is displayed:
Содержание WSAN-YMi 21
Страница 1: ...WSAN YMi 21 81 MANUAL...
Страница 43: ...43 Hydraulic module 5 7 9 kW 12 14 16 kW...
Страница 53: ...53 P 5 7 9 kW 12 14 16 kW...
Страница 112: ...112 1 phase 5 7 9KW 15 ELECTRICAL SCHEMA...
Страница 113: ...113 1 phase 12 14 16kW...
Страница 114: ...114 3 phase 12 14 16kW 15 ELECTRICAL SCHEMA...
Страница 134: ...134 Access by pwd is reserved to qualified personnel The parameters changes may cause malfunctions Structure menu...
Страница 153: ...153 20 CONTROLLER NAVIGATION MENU...
Страница 154: ...154...